Optimization of the margin expanded from the clinical to the planned target volume during intensity-modulated radiotherapy for nasopharyngeal carcinoma

نویسندگان

  • Wang Fangzheng
  • Sun Quanquan
  • Jiang Chuner
  • Ye Zhimin
  • Yang Shuangyan
  • Yu Huanhuan
  • Shi Jianfang
  • Masoto Sakamoto
  • Qin Weifeng
  • Fu Zhenfu
  • Jiang Yangming
  • Wang Yuezhen
چکیده

During the radiotherapy process, the emergence of set-up errors is nearly inevitable. Because set-up errors were not detected and corrected daily, planned target volumes were formed by expanding the clinical target volume according to each unit's experience. We optimized the margins of clinical and planned target volumes during administration of intensity-modulated radiotherapy for nasopharyngeal carcinoma. A total of 72 patients newly diagnosed with non-metastatic nasopharyngeal carcinoma and treated with Tomotherapy were prospectively enrolled in the study. For each patient, one megavoltage computed tomography scan was obtained after conventional positioning, online correction, and daily tomotherapy delivery. The interfraction set-up errors were determined using a planning CT based on the registered scan. The mean interfraction errors were -2.437±2.0529 mm, 0.0652±2.3844 mm, 0.318±1.8314 mm, and 0.197±1.8721° for the medial-lateral, superior-inferior, and anterior-posterior directions, and the direction of rotation, respectively. The total MPTV in the three directions was 7.53 mm, 1.83 mm, and 2.08 mm, respectively. The 3-mm margins in the superior-inferior and anterior-posterior directions uniformly expanded from the clinical target volume should be sufficient, and the marging in the medial-lateral direction was up to 7.5 mm. These results suggest that personalized MPTV may be adopted for intensity-modulated radiotherapy planning.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiobiological Model-Based Comparison of Three-Dimensional Conformal and Intensity-Modulated Radiation Therapy Plans for Nasopharyngeal Carcinoma

Introduction: Radiobiological modeling of radiotherapy plans are used for treatment plan comparisons. The current study aimed to compare the three-dimensional conformal radiation therapy (3DCRT) and intensity-modulated radiation therapy (IMRT) plans for nasopharyngeal cancer using radiobiological modeling. Materials and Methods: This study was conducted on 10 patients with nasopharyngeal carci...

متن کامل

A method for standardizing intensity modulated radiation therapy planning optimization for nasopharyngeal carcinoma

Background: To investigate a method for standardizing intensity modulated radiation therapy (IMRT) optimization for nasopharyngeal carcinoma (NPC), in order to reduce the influence of subjective factors. Materials and Methods: This study is based on example IMRT plans for NPC, which were randomly divided into data acquisition and data verification groups. Organs at risk (OARs) were analyzed for...

متن کامل

3-Dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis

 Background: To analyze the dosimetric and radio biologic advantages between intensity modulated radiotherapy (IMRT) and 3 dimensional conformal radiotherapy (3DCRT) and selection of optimal photon energy for IMRT treatments. Material and methods: 24 patients with localized prostate carcinoma were planned for 3DCRT and IMRT techniques. Radiation dose of 54 Gy with 2 Gy/fraction, was planned to ...

متن کامل

Comprehensive end-to-end test for intensity-modulated radiation therapy for nasopharyngeal carcinoma using an anthropomorphic phantom and EBT3 film

Background: In head and neck radiotherapy, immobilization devices can affect dose delivery. In this study, a comprehensive end-to-end test was developed to evaluate the accuracy of radiotherapy treatment. Materials and Methods: An Alderson Radiation Therapy (ART) anthropomorphic phantom with EBT3 film was used to mimic the actual patient treatment process. Ten patients treated for nasopharyngea...

متن کامل

Evaluation of the effect of dental filling material on IMRT treatment planning in patient with nasopharyngeal cancer

Introduction: Presence of dental filling material (DFM) such as amalgam in treatment patient with nasopharyngeal cancer (NPC) is common. Streaking artifact Arising from this high density material in computed tomography (scan), may lead to perturbation in dose calculation and dose delivery. Widespread performance of intensity-modulated radiotherapy (IMRT) for NPC using anterior...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2017