Sampling frequency of fetal heart rate impacts the ability to predict pH and BE at birth: a retrospective multi-cohort study.
نویسندگان
چکیده
Fetal heart rate (FHR) sampling rate used on the bedside is equal or less than 4 Hz. Current FHR analysis methods fail to detect incipient fetal acidemia. In a fetal sheep model of human labour we showed that FHR sampling rates near 1000 Hz are needed to detect fetal acidemia. Trans-abdominal fetal ECG (t-a fECG) sampling FHR at 900 Hz combined with a complex signals bioinformatics approach showed promise in a human cohort. Here we validate this finding in a retrospective human cohort study by comparing the performance of the same bioinformatics approach to predict pH and BE at birth in the cohorts with FHR sampled either at 4 Hz or at 900 Hz.The 4 Hz FHR recording data sets consisted of the open access intrapartum CTG data base with n = 552 subjects used to develop the predictive model and another cohort of prospectively recruited n = 11 labouring women to then validate it. 900 Hz FHR data set comprised two prospectively recruited t-a fECG cohorts of n = 60 and n = 23 subjects. Recruitment criteria were similar across the cohorts. We have determined the goodness of fit (R(2)) and root mean square error (RMSE) as the performance indicators of the model on each cohort.The clinical characteristics of all cohorts were similar (gestational age 280 ± 8 d; gender 50% male; birth body weight 3.5 ± 0.5 kg; pH and BE at birth 7.25 ± 0.1 and -5.7 ± 3.4 mmol L( - 1), respectively; 1' and 5' Apgar scores at birth 8.5 ± 1.4 and 9.4 ± 0.6, respectively). The 4 Hz FHR cohort rendered-for pH and BE-R(2) = 0.26 and 0.2 and RMSE = 0.087 and 3.44, respectively. This could not be confirmed in the validation cohort for neither pH nor BE prediction. The 900 Hz FHR cohort rendered-for pH and BE-R(2) = 0.9 and 0.77 and RMSE = 0.03 and 1.70, respectively, and the pH prediction was validated.In our model, lower FHR sampling rate increased the predicted error range ~3-4 fold. We show that increasing FHR sampling rate to 900 Hz improves prediction of fetal pH and BE at birth. This should improve early identification of babies at risk of brain injury.
منابع مشابه
The association Between Umbilical Coiling Index and Fetal Distress
Introduction: It is well know that fetal distress is one of the important causes of fetus perinatal morbidity and mortality. In this study, we sought to evaluate the association between umbilical coiling index and fetal distress.Material and method:This was a case- control study conducted on 90 term pregnant women. Study group had fetal distress (abnormal fetal heart rate, meconium staining, Ap...
متن کاملThe relationship between umbilical artery blood gas analysis and Apgar scores in neonates
Extended Abstract Introduction and Background : in the first minutes of life it’s important to assess newborn condition very fast but effective and decide about medical intervention as needed. Umbilical artery blood gas analysis and Apgar scoring are the most common assessment systems which studies are trying to more sensitive and accurate way.in this study we compare Apgar scoring system an...
متن کاملCorrelating multidimensional fetal heart rate variability analysis with acid-base balance at birth.
Fetal monitoring during labour currently fails to accurately detect acidemia. We developed a method to assess the multidimensional properties of fetal heart rate variability (fHRV) from trans-abdominal fetal electrocardiogram (fECG) during labour. We aimed to assess this novel bioinformatics approach for correlation between fHRV and neonatal pH or base excess (BE) at birth.We enrolled a prospec...
متن کاملComparison of pregnancy complications between gestational diabetes mellitus and normal group in Iran: a cohort study
Introduction: To compare the incidence of fetal, maternal and neonatal complications amongst women with gestational diabetes mellitus (GDM) and pregnant women with normal glucose tolerance in Shahrood. Materials and Methods: In order to compare fetal and maternal complications, for all pregnant women who were referred from private clinics and health care settings to Fatemiyeh Hospital for scree...
متن کاملAssessing the Cause of Prenatal Mortality in Medical Centers of Alborz Province
Background: Prenatal mortality is important indicator of health and health care services at birth, therefore understanding the major prenatal mortality causes will help the society to plan better prenatal and neonatal care system. Objective: This study aimed to determine the causes of Prenatal Mortality in Medical Centers of Alborz Province Methods: This was a retrospective study conducte...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physiological measurement
دوره 36 5 شماره
صفحات -
تاریخ انتشار 2015