Comparison of the BD Viper System with XTR Technology to the Gen-Probe APTIMA COMBO 2 Assay using the TIGRIS DTS system for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae in urine specimens.

نویسندگان

  • Linda M Mushanski
  • Ken Brandt
  • Nicolette Coffin
  • Paul N Levett
  • Gregory B Horsman
  • Elliot L Rank
چکیده

BACKGROUND Performances of the BD ProbeTec Chlamydia trachomatis (CT)/Neisseria Gonorrhoeae (GC) Q(x) Amplified DNA Assay reagents on a BD Viper System with XTR Technology and APTIMA COMBO 2 Assay reagents on a TIGRIS DTS platform, for detection of both CT and GC were compared. METHODS A total of 1018 first-void urine specimens were tested for the presence of CT and GC DNA using the 2 assays. RESULTS CT was detected in 143 specimens (14%). Eight specimens exhibited discordant results, and they were divided equally between the 2 assays. Based on the original results, the overall agreement for CT was 99.2%, with 97.1% and 99.5% in agreement with positive and negative specimens, respectively. Cohen's Kappa was 0.967. GC was detected in 27 specimens (2.6%). Two specimens exhibited discordant results, and they were divided equally between the 2 assays. Based on the original results, the overall agreement was 99.8%, with 96.2% and 99.9% in agreement for positive and negative specimens, respectively. Cohen's Kappa was 0.961. CONCLUSIONS There was a high level of agreement between the systems for both CT and GC detection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of three automated nucleic acid amplification systems for detection of Chlamydia trachomatis and Neisseria gonorrhoeae in first-void urine specimens.

A total of 500 first-void urine specimens were tested for the presence of Chlamydia trachomatis and Neisseria gonorrhoeae nucleic acids using ProbeTec ET reagents on a Viper platform (BD Diagnostics, Mississauga, Ontario, Canada), Aptima Combo 2 reagents on a Tigris platform (Gen-Probe, Inc., San Diego, CA), and Abbott RealTime CT/NG reagents on an m2000 platform (Abbott Molecular Diagnostics, ...

متن کامل

Clinical Evaluation of the BD ProbeTecTM Chlamydia trachomatis Q Amplified DNA Assay on the BD ViperTM System With XTRTM Technology

Background: This study evaluated the performance of the BD ProbeTec Chlamydia trachomatis Q (CTQ) Amplified DNA Assay on the BD Viper System with XTR Technology in a multicenter study. Methods: Specimens were collected at 7 geographically diverse clinical sites from 1538 women and men attending sexually transmitted disease, family planning, and obstetrics and gynecology clinics. There were 1465...

متن کامل

First report of performance of the Versant CT/GC DNA 1.0 assay (kPCR) for detection of Chlamydia trachomatis and Neisseria gonorrhoeae.

We evaluated the analytical, work flow, and clinical performance of the Versant CT/GC DNA 1.0 assay (Versant CT/GC assay, where "CT" represents Chlamydia trachomatis and "GC" represents Neisseria gonorrhoeae). The assay simultaneously detects Chlamydia trachomatis and Neisseria gonorrhoeae in swab and first-catch urine (FCU) specimens. The limit of detection (LoD) was determined to be 342 copie...

متن کامل

Comparison of the APTIMA CT and GC assays with the APTIMA combo 2 assay, the Abbott LCx assay, and direct fluorescent-antibody and culture assays for detection of Chlamydia trachomatis and Neisseria gonorrhoeae.

The Gen-Probe APTIMA Combo 2 (AC2) is a Food and Drug Administration-cleared nucleic acid amplification test (NAAT) for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae from urine and urogenital swab specimens. The Centers for Disease Control and Prevention have recommended confirmation of positive NAAT results in low-prevalence populations. APTIMA CT (ACT) and APTIMA GC (AGC) a...

متن کامل

Performance of the Abbott RealTime CT/NG for detection of Chlamydia trachomatis and Neisseria gonorrhoeae.

A multicenter clinical study was conducted to evaluate the performance characteristics of the Abbott RealTime CT/NG assay, a multiplex real-time PCR assay, for simultaneous detection of Chlamydia trachomatis and Neisseria gonorrhoeae. The specimens were collected from a total of 3,832 male and female subjects at 16 geographically diverse sites. Specimens included male and female urine samples, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Sexually transmitted diseases

دوره 39 7  شماره 

صفحات  -

تاریخ انتشار 2012