Sensitivity Enhancement for Flame Atomic Absorption Spectrometry Using an Atom Concentrator Tube, the ACT 80 Author

نویسنده

  • Jonathan Moffett
چکیده

A simple attachment to enhance the sensitivity of flame atomic absorption spectrometry (FAAS) is described along with some performance results and practical applications. An historical review is also presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dispersive liquid–liquid microextraction based on solidification of floating organic drop combined with flame atomic absorption spectrometry for determination trace amount of cobalt in water samples

An efficient, rapid, simple, and highly selective dispersive liquid–liquid microextraction basedon solidification of floating organic drop (DLLME-SFOD), combined with flame atomicabsorption spectrometry was developed for preconcentration and determination of trace amountsof cobalt in water samples. In this method, an appropriate mixture of acetone and1-undecanol was injected rapidly into the aq...

متن کامل

On-line hyphenation of hydride generation with in situ trapping flame atomic absorption spectrometry for arsenic and selenium determination.

The analytical performances of coupled hydride generation, integrated atom trap (HG-IAT) atomizer flame atomic absorption spectrometry (FAAS) systems were evaluated for determination of As and Se in biological and environmental reference materials. Arsenic and Se hydrides are atomized in air-acetylene flame-heated IAT. A new design of HG-IAT-FAAS hyphenated technique that would exceed the opera...

متن کامل

Ion Pair Dispersive Liquid-Liquid Microextraction for the Determination of Trace Amounts of Copper(II) in Soil, Multivitamin Tablet, Tea and Water Samples Using Flame Atomic Absorption Spectrometry

Ion pair dispersive liquid- liquid microextraction (IP-DLLME) method combined with flame atomic absorption spectrometry was proposed for the determination of trace amounts of copper(II). By using pyrocatechol violet as chelating agent and cetyltrimethyl ammonium bromide as an ion pairing agent, the trace amount of copper(II) was extracted in chloroform. The factors influencing the formation cop...

متن کامل

Determination of Total Mercury by Vapor Generation In Situ Trapping Flame Atomic Absorption Spectrometry

The analytical performance of non-chromatographic coupled hydride generation, integrated atom trap (HG–IAT) atomizer flame absorption spectrometry (FAAS) systems were evaluated for the determination of total mercury in environmental samples. Mercury, using formation of mercury vapors were atomized in air-acetylene flame-heated IAT. A new design of vapor generation integrated atom trap flame ato...

متن کامل

Determination of trace lead in chinese herbs by derivative flame atomic absorption spectrometry using an atom-trapping technique.

A simple and sensitive method is described for the determination of trace lead in Chinese herbs by derivative atom trapping flame atomic absorption spectrometry (D-AT-FAAS) with a modified water-cooled quartz atom-trapping tube. The effects that influence the sensitivity of the derivative method, such as the trap position, the flame conditions and the collection time, were studied. The characte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010