This work describes the development of a dedicated, fully automated sequential-injection analysis (SIA) apparatus suitable for simultaneous electrogenerated chemiluminescence (ECL) and amperometric detection. The instrument is composed of a peristaltic pump, a multiposition selection valve, a home-made potentiostat, a thin-layer electrochemical/optical flow-through cell, and a light detector. Control of the experimental sequence and simultaneous data acquisition of the light and the current intensities were performed in LabVIEW6.1. The CL reagents and the sample were first aspirated as distinct zones into the holding coil of the analyser and, then, delivered to the cell; during their travel, the individual zones mixed and the ECL reaction was initiated as soon as the mixed regents reached the cell. The utility of the analyser was demonstrated for the detection of oxalate and H2O2 based on their ECL reactions with Ru(bpy)32 and luminol, respectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison between Amperometric and Chemiluminescence methods in detection and dosimetry of cobalt-60 gamma ray emission

Background: Hydrogen peroxide (H2O2), produced by gamma ray irradiation to watery solution, was used as an analytical parameter for dosimetry of cobalt-60 (60Co) radiation. Materials and Methods: Detection of the produced H2O2 was carried out using two methods: an amperometric biosensor fabricated by immobilization of anthraquinone 2-carboxylic acid modified horseradish peroxidase on glassy car...

متن کامل

Flow-injection chemiluminescence and electrogenerated chemiluminescence determination of escitalopram oxalate in tablet form.

Rapid, simple and highly sensitive flow-injection (FI) chemiluminescence (CL) and flow-injection electrogenerated chemiluminescence (ECL) methods were developed for the determination of escitalopram oxalate (ESC), a selective serotonin reuptake inhibitor used as an antidepressant drug. The CL method was based on the CL reaction of ESC with acidic cerium(IV) and tris(2,2'-bipyridyl)ruthenium(II)...

متن کامل

Fully Automated Quantification of Insulin Concentration Using a Microfluidic-Based Chemiluminescence Immunoassay.

A fully automated microfluidic-based detection system for the rapid determination of insulin concentration through a chemiluminescence immunoassay has been developed. The microfluidic chip used in the system is a double-layered polydimethylsiloxane device embedded with interconnecting micropumps, microvalves, and a micromixer. At a high injection rate of the developing solution, the chemilumine...

متن کامل

Flow-injection chemiluminescence determination of isoniazid using on-line electrogenerated BrO2 as an oxidant

By designing a novel electrolytic flow cell, the strong oxidant BrO2 was electrogenerated on-line in KBr solution and its concentration could be readily adjusted on-line with the flow-injection technique and an electrochemical method. The chemical reaction between BrO2 and luminol in alkaline medium is accompanied by weak emission of light due to chemiluminescence (CL). It was found that the is...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of Automated Methods & Management in Chemistry

دوره 2006  شماره 

صفحات  -

تاریخ انتشار 2006