The precision of fit of cast and milled full-arch implant-supported restorations.

نویسندگان

  • Gianluca Paniz
  • Edoardo Stellini
  • Roberto Meneghello
  • Andrea Cerardi
  • Edoardo Alvise Gobbato
  • Eriberto Bressan
چکیده

PURPOSE The purpose of this study was to investigate the marginal precision of computer numeric control-milled frameworks fabricated of grade 4 commercially pure titanium or cobalt-chrome alloy through digital technology and to compare them with conventional cast frameworks. MATERIAL AND METHODS A titanium cast of a mandibular arch with six implant analogs was used as a master. The master cast was measured with a coordinate measuring machine. Fifteen rigid anatomic frameworks were created on the master cast in cast gold alloy and milled in titanium or cobalt-chrome material. The fifteen anatomic frameworks were measured in the same manner as the master cast. While the milled frameworks were measured once, at the end of the milling process, the cast anatomic frameworks were measured twice: immediately after the casting and divesting procedures and again after a technical adaptation procedure. Each anatomic framework was weighed. To compare the measurements obtained from each group of frameworks, descriptive statistics were calculated and one-way analysis of variance was performed, with values considered statistically significant at P < .05. RESULTS The mean weight of the cast frameworks was 33.41 g, the cobalt-chrome frameworks weighed 18.12 g on average, and the titanium frameworks averaged 8.7 g. The mean values for three-dimensional deviation of the center point position for each group of frameworks were 261 μm (cast frameworks before adaptation), 49 μm (cast frameworks after adaptation), 26 μm (milled frameworks in cobalt-chrome), and 26 μm (milled frameworks in titanium). CONCLUSIONS Within the limitations of this in vitro study, absolute passive fit cannot be achieved, regardless of material and fabrication technique. Anatomic milled frameworks fabricated in titanium or cobalt-chrome presented reduced center point deviation compared to cast frameworks. Titanium frameworks weighed less than cobalt-chrome and cast gold alloy frameworks.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Advantages and Limitations of Monolithic Zirconia Restorations Full Arch Implant Supported Reconstruction: Case Series

Purpose. The purpose of this retrospective case series is to evaluate the clinical advantages and limitations of monolithic zirconia restorations for full arch implant supported restorations and report the rate of complications up to 2 years after insertion. Materials and Methods. Fourteen patients received implant placement for monolithic zirconia full arch reconstructions. Four implants were ...

متن کامل

On the role of number of fixtures, surgical technique and timing of loading.

AIMS The aims of this thesis were to analyze reduced number of implants supporting full arch fixed mandibular prostheses and fixed partial dentures (FPDs), non-submerged healing and early loading in the edentulous mandible. A further aim was to evaluate fit of Computer Numerical Controlled (CNC) milled I-Bridge frameworks. MATERIAL & METHODS Paper I. One hundred and nineteen patients rehabili...

متن کامل

Precision of Fit of Titanium and Cast Implant Frameworks Using a New Matching Formula

Statement of the Problem. Fit of prosthodontic frameworks is linked to the lifetime survival of dental implants and maintenance of surrounding bone. Purpose. The purpose of this study was to evaluate and compare the precision of fit of milled one-piece Titanium fixed complete denture frameworks to that of conventional cast frameworks. Material and Methods. Fifteen casts fabricated from a single...

متن کامل

Volumetric determination of the amount of misfit in CAD/CAM and cast implant frameworks: a multicenter laboratory study.

PURPOSE The purposes of this study were (1) to evaluate the fit between implant frameworks and implants fabricated with two types of implant framework fabrication techniques: computer-aided design/computer-assisted machining (CAD/CAM) and conventional casting with the lost wax technique; and (2) to describe a digital measurement system consisting of tactile scanning and computer software progra...

متن کامل

On the role of number of fixture, surgical technique and timing of loading

On the role of number of fixtures, surgical technique and timing of loading 3 Abstract Aims: The aims of this thesis were to analyze reduced number of implants supporting full arch fixed mandibular prostheses and fixed partial dentures (FPDs), non-submerged healing and early loading in the edentulous mandible. A further aim was to evaluate fit of Computer Numerical Controlled (CNC) milled I-Bri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 28 3  شماره 

صفحات  -

تاریخ انتشار 2013