Defining acceptable limits for the metrological traceability of specific measurands.

نویسندگان

  • Renze Bais
  • Dave Armbruster
  • Rob T P Jansen
  • George Klee
  • Mauro Panteghini
  • Joseph Passarelli
  • Ken A Sikaris
چکیده

Although manufacturers are compelled by the European IVD Directive, 98/79/EC, to have traceability of the values assigned to their calibrators if suitable higher order reference materials and/or procedures are available, there is still no equivalence of results for many measurands determined in clinical laboratories. The adoption of assays with metrological traceable results will have a significant impact on laboratory medicine in that results will be equivalent across different laboratories and different analytical platforms. The IFCC WG on Allowable Errors for Traceable Results has been formed to define acceptable limits for metrological traceability chains for specific measurands in order to promote the equivalence of patient results. These limits are being developed based on biological variation for the specific measurands. Preliminary investigations have shown that for some measurands, it is possible for manufacturers to assign values to assay calibrators with a measurement uncertainty that allows the laboratory enough combined uncertainty for their routine measurements. However, for other measurands, e.g., plasma sodium, current assays are too imprecise to fulfil limits based on biological variation. Although an alternative approach based on probability theory is being investigated, the most desirable approach would be for industry to improve measurement methods so that they meet clinical requirements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

DNA concentration can specify DNA melting point in a high-resolution melting analysis master mix.

1. Algeciras-Schimnich A, Bruns DE, Boyd JC, Bryant SC, LaFortune KA, Grebe SKG. Failure of current laboratory protocols to detect lot-to-lot reagent differences: findings and possible solutions. Clin Chem 2013;59:1187–94. 2. Bais R. What information should manufacturers provide on their procedures? Clin Chem 2006; 52:1624–5. 3. Bais R, Armbruster D, Jansen RTP, Klee G, Panteghini M, Passarelli...

متن کامل

Role and Responsibilities of Laboratory Medicine Specialists in the Verification OF Metrological Traceability of in vitro Medical Diagnostics

To be accurate and equivalent, laboratory results should be traceable to higher-order references. Furthermore, their quality should fulfill acceptable measurement uncertainty as defined to fit the intended clinical use. With this aim, in vitro diagnostics (IVD) manufacturers should define a calibration hierarchy to assign traceable values to their system calibrators and to fulfill during this p...

متن کامل

Requirements for reference (calibration) laboratories in laboratory medicine.

In addition to reference measurement procedures and reference materials, reference or calibration laboratories play an integral role in the implementation of measurement traceability in routine laboratories. They provide results of measurements using higher-order methods, e.g. isotope dilution mass spectrometry and may assign values to materials to be used for external quality assessment progra...

متن کامل

The role of metrology in the field of medical devices

Medical measurements are present in the everyday life of people and are fundamental processes in prevention, diagnosis and treatment of disease. Therefore, a growing interest lies in the role of metrological decisions and conformity assessment, namely where measurements are in support of health. This paper focuses on the use of medical devices looking to enhance its metrological traceability, h...

متن کامل

Verification of in vitro medical diagnostics (IVD) metrological traceability: responsibilities and strategies.

To be accurate and equivalent, laboratory results should be traceable to higher-order references. Furthermore, their analytical performance should fulfill acceptable measurement uncertainty criteria defined to fit the intended clinical use. With this aim, In Vitro Diagnostics (IVD) manufacturers should define a calibration hierarchy to assign traceable values to their system calibrators and to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry and laboratory medicine

دوره 51 5  شماره 

صفحات  -

تاریخ انتشار 2013