3d Rotational Angiography of Transplanted Renal Arteries

نویسنده

  • GAUTE HAGEN
چکیده

Hagen, G. 3D Rotational Angiography of Transplanted Renal Arteries. A Clinical and Experimental Study. 46 pp. Uppsala. ISBN 91-506-1748-6. Th ree-dimensional rotational angiography (3D-RA) is an established method within the fi eld of interventional neuroradiology. Th e method has also a great potential in other areas with a complicated arterial anatomy. Th e purpose of this study was fi rstly to develop an investigative protocol for 3D-RA in renal transplanted patients with threatening allograft failure in diagnosing stenosis in the transplanted renal artery; secondly the protocol was evaluated and compared with a modifi ed protocol including reduced contrast medium load. Furthermore, the advantages of the 3D reconstructions compared to the angiographic images were evaluated, likewise if an extended angle of rotation reduced the artifacts in the 3D reconstructions. Th e two protocols were compared with regard to image quality and acute nephrotoxicity. Th e accuracy of Doppler ultrasonography and the result of percutaneous transluminal angioplasty (PTA) were also assessed. 3D-RA was consecutively performed in 57 renal transplanted patients with suspicion of renal artery stenosis. A signifi cant stenosis was found in 49% of the patients. Th e 3D reconstructions profi led 43% of the transplant renal artery stenoses better than the angiographic images. An extended angle of rotation reduced the artifacts. Th ere was no statistical diff erence regarding image quality between the two protocols, and the renal function was equally aff ected in both protocols. Doppler ultrasonography sensitivity was 100%; specifi city was 48% and positive predictive value 67%. PTA had a technical success rate of 92% and a clinical success rate of 75% after 3 months. 3D-RA is a helpful supplement in cases with complicated vascular anatomy, especially when PTA may be indicated. Th e 3D reconstructions profi le the course of the artery more frequently than the angiographic images and support PTA. Th e 3D reconstructions are degraded of artifacts. Sampling artifacts can be diminished by increased C-arm rotation and increased number of projections. Th e distortions caused by beam hardening remain to be solved.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anatomical Evaluation of Renal Arteries and Veins in Kidney Donors by CT Angiography

Abstract Background: Renal transplantation (RT) is the transplantation of a kidney into a patient with end-stage renal disease and has become the treatment of choice for most patients with end-stage renal disease. The knowledge of renal vascular variations is of a great importance for the surgeons who approach the kidneys from the retroperitoneal o...

متن کامل

Simultaneous bilateral internal carotid artery 3D rotational angiography.

We simultaneously injected both internal carotid arteries (ICAs) during 3D rotational digital subtraction angiography in a patient with a ruptured anterior communicating artery (Acom) aneurysm and vasospasm. Shaded surface display (SSD) images from this acquisition provided more anatomic detail than did SSD images created from individual ICA 3D rotational digital subtraction angriography. In th...

متن کامل

Non Contrast-Enhanced 3D MR Angiography of Renal Arteries using a Novel Inversion Recovery Steady State Free Precession Technique: Our Initial Experience

Figure 2. (A) Non contrast IR-SSFP MRA in a patient with transplanted right kidney demonstrates a mild less than 50% luminal narrowing at the anastamosis (long white arrow) with ipsilateral native right distal common iliac artery (short arrow). First order branches (arrowheads) are unremarkable. (B) Non contrast IR-SSFP MRA in a patient with transplanted right kidney demonstrates normal transpl...

متن کامل

Clinical usefulness of unsubtracted 3D digital angiography compared with rotational digital angiography in the pretreatment evaluation of intracranial aneurysms.

BACKGROUND AND PURPOSE Three-dimensional digital subtraction angiography (DSA) is useful as a supplement to 2D DSA in the pretreatment evaluation of intracranial aneurysms. However, the clinical efficacy of 3D digital angiography (DA) that is generated from unsubtracted rotational images has not been established. The purpose of this study was to assess whether 3D DA provides additional useful i...

متن کامل

3D Reconstruction of Cerebral Blood Flow and Vessel Morphology from X-Ray Rotational Angiography

Three-dimensional (3D) information on blood flow and vessel morphology is important when assessing cerebrovascular disease and when monitoring interventions. Rotational angiography is nowadays routinely used to determine the geometry of the cerebral vasculature. To this end, contrast agent is injected into one of the supplying arteries and the x-ray system rotates around the head of the patient...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004