Shielding high energy accelerators.
نویسنده
چکیده
After introducing the subject or shielding high energy accelerators, point source, line-of-sight models, and in particular the Moyer Model, are discussed. Their use in the shielding of proton and electron accelerators is demonstrated and their limitations noted, especially in relation to shielding in the forward direction provided by large, flat walls. The limitations of reducing problems to those using a cylindrical geometry description are stressed. Finally the use of different estimators for predicting dose is discussed. It is suggested that dose calculated from track-length estimators will generally give the most satisfactory estimate.
منابع مشابه
Dosimetric Quantities and Neutron Spectra Outside the Shielding of Electron Accelerators
Typical neutron spectra as found at high energy electron accelerators outside concrete shielding of various thicknesses (at 90 degrees) have been calculated at three electron energies (100 MeV, 1 and 10 GeV) with the FLUKA Monte Carlo transport code. The results have provided useful information about neutron attenuation lengths and about the fraction of neutrons with energy larger than 20 MeV, ...
متن کاملNeutron Energy and Time-of-flight Spectra Behind the Lateral Shield of a High Energy Electron Accelerator Beam Dump, Part II: Monte Carlo Simulations
Energy spectra of high-energy neutrons and neutron time-of-flight spectra were calculated for the setup of experiment T-454 performed with a NE213 liquid scintillator at the Final Focus Test Beam (FFTB) facility at the Stanford Linear Accelerator Center. The neutrons were created by the interaction a 28.7 GeV electron beam in the aluminum beam dump of the FFTB which is housed inside a thick ste...
متن کاملNeutron source strength measurements for Varian, Siemens, Elekta, and General Electric linear accelerators
The shielding calculations for high energy (>10 MV) linear accelerators must include the photoneutron production within the head of the accelerator. Procedures have been described to calculate the treatment room door shielding based on the neutron source strength (Q value) for a specific accelerator and energy combination. Unfortunately, there is currently little data in the literature stating ...
متن کاملNeutron deep-penetration calculations and shielding design of proton therapy accelerators
Proton therapy accelerators have become increasingly popular for cancer treatment in recent years. In Taiwan, the first proton treatment center equipped with a 235 MeV proton cyclotron in Linkou Chang Gung Memorial Hospital is ready for beam commissioning. Proton therapy accelerators in the energy range could potentially produce intense secondary neutrons, which must be carefully evaluated and ...
متن کاملRadiation protection at high energy electron accelerators.
An overview is presented of radiation protection at high energy electron accelerator facilities. By 'high energy' is meant the energy domain beyond a few tens of MeV, where electromagnetic showers are the determining and dominant factor for beam interactions with matter. The basic components of electron accelerators are described and their potential impact on radiation safety. The paper then co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiation protection dosimetry
دوره 96 4 شماره
صفحات -
تاریخ انتشار 2001