Control of aerosol contaminants in indoor air: combining the particle concentration reduction with microbial inactivation.
نویسندگان
چکیده
An indoor air purification technique, which combines unipolar ion emission and photocatalytic oxidation (promoted by a specially designed RCI cell), was investigated in two test chambers, 2.75 m3 and 24.3 m3, using nonbiological and biological challenge aerosols. The reduction in particle concentration was measured size selectively in real-time, and the Air Cleaning Factor and the Clean Air Delivery Rate (CADR) were determined. While testing with virions and bacteria, bioaerosol samples were collected and analyzed, and the microorganism survival rate was determined as a function of exposure time. We observed that the aerosol concentration decreased approximately 10 to approximately 100 times more rapidly when the purifier operated as compared to the natural decay. The data suggest that the tested portable unit operating in approximately 25 m3 non-ventilated room is capable to provide CADR-values more than twice as great than the conventional closed-loop HVAC system with a rating 8 filter. The particle removal occurred due to unipolar ion emission, while the inactivation of viable airborne microorganisms was associated with photocatalytic oxidation. Approximately 90% of initially viable MS2 viruses were inactivated resulting from 10 to 60 min exposure to the photocatalytic oxidation. Approximately 75% of viable B. subtilis spores were inactivated in 10 min, and about 90% or greater after 30 min. The biological and chemical mechanisms that led to the inactivation of stress-resistant airborne viruses and bacterial spores were reviewed.
منابع مشابه
بررسی مقایسهای غلظت ذرات معلق در هوای داخل با هوای آزاد خارج بیمارستان دنا شیراز
Abstract Introduction & Purpose: Indoor air quality, particularly in health care facility, is important. One of the most important factors affect the air quality is aerosols due to carrying microorganisms and deposit in the respiratory tract. Therefore, the purpose of this study was to measure the concentration of suspended particles in outdoor and indoor of Dena hospital and determine the re...
متن کاملAssessment of air pollution in exercise centers and health risks
Background: In recent years, Tehran has faced major problems with air pollution for many reasons, and this issue has become a critical point in most of the days. However, less attention has been paid to the indoor air pollutants in exercise centers and their possible health effects. In this research, it was tried to briefly describe the characteristics and chemical composition of the aerosols p...
متن کاملLiteratur Review and Parametric Study: Indoor Particle Resuspension by Human Activity
Once an aerosol contaminant is introduced into an indoor environment, it can remain in the air, deposit on interior surfaces or attach to dust particles already present. Human activity, such as walking and cleaning, resuspends contaminated particles, regenerating airborne contaminants. This report is a literature review on the effects of human activity on particle re-suspension in indoor enviro...
متن کاملبررسی غلظت ذرات معلق در هوای داخل کلاس و هوای بیرون و عوامل تأثیرگذار آن در مدارس راهنمایی و دبیرستان شهر یزد
Abstract Introduction: Airborne pollution in such public environments as schools has adverse health effects on pupils and teachers who spend a noticeable amount of time in the school. Therefore, this study aimed to measure the suspended particles concentration of indoor and outdoor air of Yazd schools as well as to determine the influencing parameters on the pollution intensity. Metho...
متن کاملIndoor and Outdoor Aerosol Particle Size Characterization in Helsinki
This thesis presented analysis and results from long-term and short-term aerosol particle measurements of indoor-outdoor total particle number and size distributions in Helsinki. This thesis focused on the temporal–spatial variations of aerosol particle number size distributions, the factors (including local wind, ambient temperature, and traffic density) influencing the particle number size di...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Environmental science & technology
دوره 41 2 شماره
صفحات -
تاریخ انتشار 2007