Generation 04 sodium slides and generation 04 reference fluid evaluated for use with the Ektachem 400 Analyzer.

نویسندگان

  • R M Jack
  • W Noble
چکیده

Evaluation of a new generation of sodium slides and reference fluid for use with the Kodak Ektachem 400 Analyzer demonstrated improved performance in generation 04 over the previous generation 03 slide for sodium determinations. A decrease in between-replicate imprecision and a correction of the "serum" assigned values of the calibrators used to calibrate the slide used with the reference fluid account for the improvement. When generation 04/Ektachem results (y) were compared with results obtained with a Beckman ion-selective electrode (x), linear regression statistics were: slope = 0.88, y-intercept = 15.4 mmol/L, and Syx = 2.1 mmol/L. The average fixed bias in comparison with the Beckman electrode decreased from +1.9 mmol/L with generation 03 to -0.6 mmol/L with generation 04 materials. Random error is indicated by a decrease in Syx from 2.8 mmol/L for generation 03 to 2.1 mmol/L for generation 04. Application of Deming's regression, a more accurate portrayal of the generation 04 sodium data set, produces a slope of 1.0 and a y-intercept of -0.6 mmol/L.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Factitiously high sodium activities on the Ektachem 400 owing to interferences by high gamma-globulin concentrations.

Sera from patients with above-normal gamma-globulin concentrations give sodium values as much as 10% higher when measured in the Kodak Ektachem 400 analyzer than results obtained with the Beckman Astra-8 analyzer. Results obtained with the Astra were in agreement with flame photometry. A similar relative bias was observed for potassium measurement in the Ektachem. This discrepancy was corrected...

متن کامل

Ektachem slides for direct potentiometric determination of sodium in plasma: effect of natremia, blood pH, and type of electrolyte reference fluid on concordance with flame photometry and other potentiometric methods.

With electrolyte reference fluid (ERF)00, results from Kodak Ektachem slides for the direct potentiometric assay of sodium in plasma were significantly correlated with results from flame photometry, but also appeared to be systematically higher, especially in hypernatremic patients. Indirect potentiometry with the Technicon RA-1000 yielded intermediate values. In 23 hypernatremic patients with ...

متن کامل

Clinical evaluation of Eastman Kodak's Ektachem 400 Analyzer.

We evaluated the performance of the Kodak Ektachem 400 Analyzer in a 16-week clinical trial. We assessed four potentiometric tests and nine colorimetric tests for precision and correlation with results obtained some other commonly used instruments (Technicon SMA II and C800 System, Du Pont aca II, and Baker CentrifiChem). The comparison was favorable for all tests except albumin, sodium, and ca...

متن کامل

Discrepancies between sodium concentrations measured by the Kodak Ektachem 700 and by dilutional and direct ion-selective electrode analyzers.

We have identified rare (approximately 0.2% of all samples), but clinically significant, discrepancies between serum or plasma sodium concentrations measured with the Kodak Ektachem 700's direct ion-selective electrode (ISE) method and concentrations measured with two other analyzers: the Beckman Synchron CX3's dilutional ISE instrument and the Radiometer KNA2 instrument for sodium-potassium an...

متن کامل

Applicability of the Ektachem 400 analyzer for assaying analytes in miscellaneous body fluids.

The Ektachem analyzer, a slide-film chemistry technology, demonstrated applicability to non-serum, non-urine stimulated and actual clinical specimens having a wide range of protein concentration and pH. The simulated specimens studied had pH and protein that ranged from 2 to 9 and 0 to 88 g/L, respectively. Actual patients' specimens studied, which had protein concentrations ranging from 0.1 to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 33 6  شماره 

صفحات  -

تاریخ انتشار 1987