Comparative Study of Pulp Vitality in Primary and Young Permanent Molars in Human Children with Pulse Oximeter and Electric Pulp Tester
نویسندگان
چکیده
AIM AND OBJECTIVE The purpose of this study was to compare the pulp testing methods (pulse oximetry and electric pulp test) in primary and young permanent teeth of children. MATERIALS AND METHODS The study included a total of 155 children aged 4 to 15 years. Twenty children formed control group I. Study group included all healthy, 85 primary 2nd molars in group II and 85 permanent 1st molars in group III. Fifty children needing endodontics treatment formed test group IV. The readings were recorded as true positive (TP), false positive (FP), true negative (TN), false negative (FN). Based on this, the sensitivity, specificity, positive predictive value and negative predictive value were calculated for each method. The results were statistically analyzed using Chi-square test. RESULTS On comparing pulse oximetry with electric pulp test 'p-value' was found to be 0.487 and 1.00 for groups 1 and 2 respectively and was statistically not significant. Whereas 'p-value' for groups 3 and 4 was < 0.0001 and 0.003 respectively and was statistically highly significant. CONCLUSION The present study indicates that pulse oximetry can be used as a routine method for assessing the pulp vitality in primary, young permanent and mature permanent teeth. How to cite this article: Shahi P, Sood PB, Sharma A, Madan M, Shahi N, Gandhi G. Comparative Study of Pulp Vitality in Primary and Young Permanent Molars in Human Children with Pulse Oximeter and Electric Pulp Tester. Int J Clin Pediatr Dent 2015;8(2):94-98.
منابع مشابه
بررسی اثر سن بیمار بر پاسخ دندان به پالپ تستر الکتریکی
Background and Aims: Electric pulp tester is a valuable instrument to examine tooth’s pulp vitality. There is no agreement about the response of immature teeth to electric pulp tester and the reason is expressed as the failure of nerve fibers’ development. The aim of this study was to investigate the effect of patient’s age on the tooth response to electric pulp tester. Materials and Method...
متن کاملبررسی تاثیر تغییرات حرارتی بر پاسخ دندان به پالپ تستر الکتریکی
Background and Aims: The vitality pulp tests are necessary for diagnosis of pulpal disease and differentiation between endodontic and non-endodontic diseases. Thermal and electrical tests are conventional methods for evaluation of pulp vitality. The purpose of this study was to evaluate the effect of thermal changes on the tooth response to the electric pulp tester. Materials and Methods: In t...
متن کاملDental pulp neurophysiology: part 2. Current diagnostic tests to assess pulp vitality.
In this second part of our 2-part review, we discuss recent research about pulp tests that determine the vitality of the tooth and clinically accepted pulp testers. A pain response to hot, cold or an electric pulp tester indicates the vitality of only a tooth's pulpal sensory supply; the response does not give any idea about the state of the pulp. Although the sensitivity of these tests is high...
متن کاملEvaluation of efficacy of a pulse oximeter to assess pulp vitality.
BACKGROUND To evaluate the efficacy of pulse oximeter as a pulp vitality tester. MATERIALS AND METHODS The sample group consisted of 60 patients of age 15 to 30 years with normal maxillary anterior teeth. Thirty nonvital teeth with complete endodontic fillings were tested as control group. Systemic oxygen saturation values from the patient's fingers served as the control sample for comparison...
متن کاملدرمان پالپ زنده در دندانهای مولر دایمی نابالغ علامتدار: گزارش 3 مورد
Endodontic treatment of immature permanent teeth accompanies with several issues. The primary goal when treating such teeth is to maintain pulp vitality so that root development can occur normally. Indications and requirements for vital pulp therapy include asymptomatic and reversible pulpitis. Also there are controversial opinions regarding the ultimate clinical treatment of the vital pulp the...
متن کامل