Effects of Different Levels of Intraocular Stray Light on Kinetic Perimetry Findings
نویسندگان
چکیده
PURPOSE To evaluate the effect of different levels of intraocular stray light on kinetic perimetry findings. METHODS Twenty-five eyes of 25 healthy young participants were examined by automated kinetic perimetry (Octopus 900) using Goldmann stimuli III4e, I4e, I3e, I2e, and I1e. Each stimulus was presented with a velocity of 3°/s at 24 meridians with 15° intervals. Four levels of intraocular stray light were induced using non-white opacity filter (WOF) filters and WOFs applied to the clear plastic eye covers of the participants. The visual acuity, pupil diameter, isopter area, and kinetic sensitivity of each meridian were analyzed for each WOF density. RESULTS Visual acuity deteriorated with increasing WOF densities (p < 0.01). With a visual acuity of 0.1 LogMAR units, the isopter areas for III4e, I4e, I3e, I2e, and I1e decreased by -32.7 degree2 (-0.2%), -255.7 degree2 (-2.6%), -381.2 degree2 (-6.2%), -314.8 degree2 (-12.8%), and -59.2 degree2 (-15.2%), respectively; kinetic sensitivity for those stimuli decreased by -0.1 degree (-0.1%), -0.8 degree (-1.4%), -1.6 degree (-3.7%), -2.7 degree (-9.7%), and -1.7 degree (-16.2%), respectively. The pupil diameter with each WOF density was not significantly different. CONCLUSION Kinetic perimetry measurements with a high-intensity stimulus (i.e., III4e) were unaffected by intraocular stray light. In contrast, measurements with the I4e, I3e, I2e, and I1e stimuli, especially I2e and I1e, were affected. Changes in the shape of the isopter resulting from opacity must be monitored, especially in cases of smaller and lower-intensity stimuli.
منابع مشابه
The robustness of various forms of perimetry to different levels of induced intraocular stray light.
PURPOSE To compare directly the robustness of standard automated perimetry (SAP), short-wavelength automated perimetry (SWAP), frequency-doubling perimetry (FDP), and grating-resolution perimetry (GRP) stimuli to different degrees of intraocular stray light induced by commercially available opacity-containing filters. METHODS Five white opacity filters of increasing density were used to simul...
متن کاملLight scatter and disability glare after intraocular lens implantation.
F orward light scatter measurement provides information about optical imperfections as the cause of glare disability. Glare disability refers to a reduction in visual performance caused by a glare source, resulting in retinal contrast loss secondary to intraocular stray light. Lens extraction reverses the strong age increase in stray light, which is considered an independent source of symptoms....
متن کاملSome observations on the relation between intraocular pressure reduction and the progression of glaucomatous visual loss.
A quantitative measure of visual field loss associated with kinetic perimetry in chronic open-angle glaucoma (COAG) is discussed. With this new technique an analysis of covariance is applied to a retrospective study of 41 COAG patients. It suggests that reduction of intraocular pressure may not be uniformly effective in controlling the progression of the disease.
متن کاملThe effect of induced intraocular straylight on perimetric tests.
PURPOSE To investigate the effect of intraocular straylight (IOS) on threshold measurements made by four types of perimetry: standard automated perimetry (SAP), frequency-doubling technology (FDT) perimetry, flicker-defined form (FDF) perimetry, and the Moorfields Motion Displacement Test (MDT). METHODS Six healthy young (21-29 years) psychophysically experienced observers were tested five ti...
متن کاملEffect of aspherical and yellow tinted intraocular lens on blue-on-yellow perimetry.
PURPOSE To investigate the possible effect of aspherical or yellow tinted intraocular lens (IOL) on contrast sensitivity and blue-on-yellow perimetry. METHODS This prospective randomized bilateral double-masked clinical study included 52 patients with visually significant bilateral cataracts divided in two groups; 25 patients (50 eyes) received aspherical intraocular lens in one eye and spher...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 10 شماره
صفحات -
تاریخ انتشار 2015