Handle old laryngoscopes with care.

نویسندگان

  • Shriram Vaidya
  • Suman Lata Gupta
  • Priya R
  • M V S Satya Prakash
چکیده

To cite: Vaidya S, Gupta SL, R P, et al. BMJ Case Rep Published online: [please include Day Month Year] doi:10.1136/bcr-2014207084 DESCRIPTION A 30-year-old woman with fibroid uterus was operated on for myomectomy under general anaesthesia. Preoperative evaluation revealed adequate mouth opening, neck extension, thyromental distance and Mallampati grade 1. In the operating room, anaesthesia was induced with fentanyl and propofol under standard monitoring. Muscle relaxation was achieved with vecuronium. Laryngoscopy was attempted with a size 3 McIntosh laryngoscope blade after mask ventilating the patient for 3 min. Laryngoscopy revealed a Cormack Lehane grade 3 view. External laryngeal manipulation with increased axial force along the laryngoscope handle was attempted. During this time, the laryngoscope blade along with the hinge piece separated from rest of the handle at the weld line. Fortunately, none of the batteries or other parts slipped into the patient’s oropharynx. The patient was mask ventilated and laryngoscopy was attempted with another laryngoscope. Subsequent tracheal intubation was successful with help of a stylet. On closer examination of the damaged laryngoscope handle, breakage was found along the line where the knurled barrel of the handle was welded into the proximal cast fitting of the hinge piece (figures 1 and 2). Failure of welding can be attributed to laryngoscope handle wear; the laryngoscope had clearly been in use for many years. The weld line between the hinge piece and knurled barrel of the handle acts as a fulcrum and is subjected to a force of 10–30 newton during laryngoscopy. This force can reach 100 newton during a difficult laryngoscopy and in our case could have caused the failure of the welding. Breakage at hinge and ingestion and loss of rivet in a MacCoy blade have been reported earlier.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bacterial Contamination and Disinfection Status of Laryngoscopes Stored in Emergency Crash Carts

Objectives To identify bacterial contamination rates of laryngoscope blades and handles stored in emergency crash carts by hospital and area according to the frequency of intubation attempts. Methods One hundred forty-eight handles and 71 blades deemed ready for patient use from two tertiary hospitals were sampled with sterile swabs using a standardized rolling technique. Samples were conside...

متن کامل

Airway management disasters in the ICU - lessons learned?

The C-MAC video laryngoscope substantially reduced poor glottic views and increased intubation success in ICU patients with at least one predictor for difficult intubation. However, all video-assisted and optical intubation devices have different view angles, thus producing different images with particular distortion, and even experts in 'old-fashioned' airway management need a substantial leve...

متن کامل

Aids for facilitation of difficult tracheal intubation review and recent advances.

Management of difficult tracheal intubation has been facilitated by different techniques which include the use of stylets, introducers, intubating laryngeal mask airway, as well as by the development of special laryngoscope blades and fiberoptic laryngoscopes. The most recent advances for facilitation of difficult tracheal intubation is the introduction of the video-assisted laryngoscopes. The ...

متن کامل

Successful airway management using a MultiViewScope handle with a stylet scope in a patient with Schwartz–Jampel syndrome

Schwartz-Jampel syndrome (SJS) is a rare disorder characterized by micrognathia, kyphoscoliosis, and myotonia. The greatest challenge in the anesthetic management of patients with SJS is performing tracheal intubation. The MultiViewScope (MVS) is a video laryngoscope system in which the video monitor handle can be attached to a stylet scope, laryngoscope blade, or fiberscope. We report a 21-mon...

متن کامل

The video revolution: a new view of laryngoscopy.

The development of less expensive, smaller, and more reliable video cameras has revolutionized the design of laryngoscopes and the process of endotracheal intubation. The term video laryngoscopy defines a broad range of devices, distinct from fiberoptic bronchoscopes, in which a video camera is used in place of line-of-sight visualization to accomplish endotracheal intubation. Over a dozen lary...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMJ case reports

دوره 2014  شماره 

صفحات  -

تاریخ انتشار 2014