Homogeneous immunoassay of whole-blood samples.

نویسندگان

  • B K Merenbloom
  • B J Oberhardt
چکیده

Proof of principle has been shown for a rapid, quantitative, homogeneous immunoassay capable of analyzing whole-blood samples. The assay was performed with test cards and a small instrument designed for use at the point of care. The immunoassay has an immunological "front end" combined with a coagulation cascade chemistry "back end" and is made possible by combining two patented technologies: (a) a serine protease inhibitor [Porter and Bruhnke, Photochem and Photobiol 1990; 51(1):37] and (b) paramagnetic iron oxide particles (PIOP) in a mixture of buffers and coagulation assay components supplied as a dry film in a test-card reaction chamber [Oberhardt et al., Clin Chem 1991;37:520]. A model steric-hindrance immunoassay based on these technologies was established for the measurement of biotin. The calibration curve was developed by measuring plasma samples supplemented with biotin. The reagents were inhibited biotinylated thrombin, anti-biotin monoclonal antibody, and PIOP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Plasma vs whole blood for therapeutic drug monitoring of patients receiving FK 506 for immunosuppression.

By retrospective analysis of 13,000 blood samples obtained from 248 patients receiving FK 506 therapy, we compared the suitability of plasma with that of whole blood as the matrix for therapeutic drug monitoring of FK 506. The plasma concentrations did not correlate with the concentrations in whole blood (r = 0.56). In contrast to plasma samples (analyzed by enzyme immunoassay), FK 506 was dete...

متن کامل

Rapid and sensitive detection of troponin I in human whole blood samples by using silver nanoparticle films and microwave heating.

BACKGROUND Cardiovascular diseases are among the leading causes of mortality in developed countries. It is widely recognized that troponin I (TnI) can be used for the assessment of a myocardial infarction. METHODS We investigated the use of the microwave-accelerated and metal-enhanced fluorescence (MA-MEF), a technique based on the combined use of low-power microwave heating, silver nanoparti...

متن کامل

Evaluation of the PATHFAST Chemiluminescent Enzyme Immunoassay for Measuring Progesterone in Whole Blood and Serum of Mares

Evaluation of a new chemiluminescent enzyme immunoassay, the PATHFAST assay system (PATHFAST), for measurement of circulating progesterone in mares was performed. Five mares at the mid-luteal stage were administrated a single i.m. injection of prostaglandin F2α analog (PGF2α; cloprostenol 250 μg/ml), and then blood samples were collected from the jugular vein at 0, 15, 30 and 45 min, at one-hou...

متن کامل

Fast Reading of C-Reactive Protein in Whole Blood in Hematology Analyzers

A new homogeneous immunoassay of whole blood C-reactive protein based on the use of magnetic fieldassisted agglutination of polyclonal anti-CRP coated superparamagnetic particles is described. These particles self-organize into linear chains under an appropriate magnetic field which considerably increase the colliding frequency and thus, the probability to form links between ligand and receptor...

متن کامل

Whole-blood counting immunoassay as a short-turnaround test for detection of hepatitis B surface antigen, anti-hepatitis C virus antibodies, and anti-Treponema pallidum antibodies.

Whole-blood samples were used for a counting immunoassay (CIA) with the aim of developing a short- turnaround test. After optimization of the CIA, hepatitis B surface antigen (HBsAg), anti-hepatitis C virus antibodies (anti-HCV), and anti-Treponema pallidum antibodies (anti-TP) were detected as efficiently as by an enzyme immunoassay (EIA) with serum samples. The correlations between whole-bloo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 41 9  شماره 

صفحات  -

تاریخ انتشار 1995