Hemoglobin by first derivative spectrophotometry: extent of hemolysis in plasma and serum collected in vacuum container devices.
نویسندگان
چکیده
Commonly obtained clear plasma or serum samples contain small amounts of hemoglobin derived from either naturally occurring processes or from collection trauma. Using the recently evaluated, highly specific, sensitive, quantitative procedure of first derivative spectroscopy, the hemoglobin concentration in nine types of vacuum collection containers was measured, including three types of anticoagulant, three tube sizes, and tubes with or without serum separators. Using this procedure, reference values were established for plasma and serum hemoglobin. These values are the result of the combined effect of red cell trauma during the collection, interaction with the anticoagulant or the serum separator material, and physiologic changes. The observed hemoglobin levels were best described by a log normal distribution pattern. The three plasma collection samples showed lower average values than the serum samples. The citrate anticoagulant gave the lowest plasma hemoglobin average value of 32.7 mg per L (3.27 mg per dl) 9.2 to 123 mg per L (0.92 to 12.3 mg per L 2SD range). It is concluded that the average hemoglobin concentration owing to the collection procedure is less than 100 mg per L (10 mg per dl). A serum or plasma hemoglobin concentration over 200 mg per L (20 mg per dl) is probably due to abnormal physiologic causes and not collection artefact. Serum or plasma hemoglobin measurements evaluated by these criteria can be relied upon as an accurate approximation of excess hemoglobin produced by a pathologic hemolytic process such as acute autoimmune hemolytic anemia, major blood group incompatibility or paroxysmal hemoglobinuria.
منابع مشابه
Identification of a Hemolysis Threshold That Increases Plasma and Serum Zinc Concentration123
Background: Plasma or serum zinc concentration (PZC or SZC) is the primary measure of zinc status, but accurate sampling requires controlling for hemolysis to prevent leakage of zinc from erythrocytes. It is not established how much hemolysis can occur without changing PZC/SZC concentrations.Objective: This study determines a guideline for the level of hemolysis that can significantly elevate P...
متن کاملTechnical Factors Involved in the Measurement of Circulating MicroRNA Biomarkers for the Detection of Colorectal Neoplasia
BACKGROUND Circulating miRNAs are emerging as promising blood-based biomarkers for colorectal and other human cancers; however, technical factors that confound the development of these assays remain poorly understood and present a clinical challenge. The aim of this study was to systematically evaluate the effects of factors that may interfere with the accurate measurement of circulating miRNAs...
متن کاملSimultaneous Determination of Losartan and Hydrochlorothiazide in Pharmaceutical Preparations by Derivative and Ratio Derivative Spectrophotometry
Background & Aims: Losartan is a non-peptide potent antihypertensive agent that acts through blocking angiotensin II receptors. Hyzaar® is a combination product that contains two drugs, losartan and hydrochlorothiazide, used to lower high blood pressure. There are some reports regarding simultaneous measurement of the drugs in pharmaceutical and biological samples which includes HPLC, CE, CEC, ...
متن کاملComparison of Methodologies to Detect Low Levels of Hemolysis in Serum for Accurate Assessment of Serum microRNAs
microRNAs have emerged as powerful regulators of many biological processes, and their expression in many cancer tissues has been shown to correlate with clinical parameters such as cancer type and prognosis. Present in a variety of biological fluids, microRNAs have been described as a 'gold mine' of potential noninvasive biomarkers. Release of microRNA content of blood cells upon hemolysis dram...
متن کاملApplication of Derivative Spectrophotometry to Determine the Relation Between Color Intensity and Dye Concentration of Madder
The Derivative Spectrophotometry usually improves resolution bands, eliminates the influence of background and provides more defined fingerprints than original spectra, hence enhancing the detectability of minor spectral features. In this work, different madder types were collected and applied for dyeing woolen yarns used in Persian carpet in conventional pre-mordanting and dyeing process with ...