A simple and effective method for differentiating GFP and YFP by flow cytometry using the violet laser.
نویسندگان
چکیده
GFP and YFP are fluorescent proteins that are widely used in various cellular assays (1). The 488-nm blue laser, that is standard on virtually all flow cytometers, efficiently excites both proteins. GFP and YFP signals can be discriminated using a customized filter configuration involving a 550/30-nm band pass for YFP, a 510/20-nm band pass filter for GFP, with a 525-nm short-pass dichroic mirror between them (2). However, on most cytometers, GFP/YFP signals are detected using a single band pass filter (usually in the range 500–550 nm). The requirement for using a customized setup deters some investigators from using these fluorescent proteins in conjunction, and is a rate-limiting step for others. In addition, because this method relies on using 510/20-nm and 550/30nm band pass filters instead of a 525/50-nm band pass filter, only a fraction of the photons emitted by GFP/YFP are detected, meaning sensitivity is suboptimal. In recent years, 405-nm violet lasers have become standard on most flow cytometers, and these lasers are capable of exciting additional fluorochromes. The standard configuration of filters off the violet laser includes a band pass in the range of 500–550 nm, capable of detecting Amcyan, Quantum Dot 525, Brilliant Violet 510, and Aqua live/dead fixable stain. In this communication, we demonstrate that the 405-nm violet laser weakly excites GFP but not YFP, allowing discrimination between them using a 525/50-nm band pass filter. NK cells from Ncr1/GFP and Nkp46/R26R mice express GFP and YFP, respectively (3,4). Discriminating between GFP and YFP would allow tracking distinct populations of NK cells that had been adoptively transferred to the same mouse, which could be very useful in multiple scenarios. Examining the excitation spectra of GFP, we noticed that the 405-nm violet laser caused the excitation of GFP, which could be detected using a 525/50-nm band pass filter off the 405-nm violet laser (the “prototypical” channel used for detecting the Amcyan/Aqua live/dead fixable stain). Indeed, a distinct signal could be detected in the “Amcyan” channel when Ncr1/GFP splenocytes were used, but a much lower or negligible signal was evident when Nkp46-CRE/R26-YFP splenocytes were used (Figs. 1a and 1b). Importantly, the GFP/YFP signals could still be discriminated when the cells were mixed together (Fig. 1c), providing evidence that GFP1 and YFP1 cells in a mixture can be separately analyzed or sorted using this method. Concurrent use of GFP and YFP could be highly advantageous in many cellular assays, particularly when using cells of transgenic mice whose cells express fluorescent proteins, because generating mice with alternative fluorescent proteins can take a lot of time and effort. In this report, we demonstrated that the 405-nm violet laser excitation could be used to discriminate GFP and YFP signals. Using the violet laser to distinguish GFP and YFP has several advantages. First, the standard setup of the flow cytometer could be used, obviating the need for exchanging filters and dichroic mirrors. In the previous method the light coming off the blue 488-nm laser is partitioned into two channels corresponding to GFP and YFP. In our method the light is not partitioned, and a single channel (normally used for detecting FITC) is used to detect both proteins, allowing for detection of weaker signals. In addition, the previous method also required the use of an additional detector off the blue 488-nm laser, which must come at the expense another fluorochrome that is excited by this laser (such as PE, PE-TXRD, PE-Cy5, PE-Cy7, or Percp-Cy5.5). By contrast, our method exploits a channel (525/50-nm band pass filter off the 405-nm laser), for which far fewer
منابع مشابه
P-6: Flow Cytometry: Assessment of Protamine Deficiency by CMA3 Staining and Apoptotic Bodies
Background: Chromomycin A3 (CMA3) staining, with the slide method or fluorescence microscopy, is widely used for indirect assessment of protamine deficiency in a semen sample. Flow cytometry is the most suitable tool which to improve assessment accuracy, both in terms of statistical analysis and to prevent observer variation. This study provides a simple procedure to account for merocyanine 540...
متن کاملOptimized Method for Reticulocyte Counting: Simple, Accurate, and Comparable to Flow Cytometry
Background: Reticulocytes are immature red blood cells with RNA, spending the final stages of their maturation in the peripheral blood. The number of reticulocytes in the peripheral blood is the salient evidence of the effectiveness of bone marrow to produce red blood cells. Currently, reticulocyte count is done manually or automatically in clinical laboratories. Difficulties and limitations of...
متن کاملFluorescence resonance energy transfer analysis of cell surface receptor interactions and signaling using spectral variants of the green fluorescent protein.
BACKGROUND Fluorescence resonance energy transfer (FRET) is a powerful technique for measuring molecular interactions at Angstrom distances. We present a new method for FRET that utilizes the unique spectral properties of variants of the green fluorescent protein (GFP) for large-scale analysis by flow cytometry. METHODS The proteins of interest are fused in frame separately to the cyan fluore...
متن کاملمهار بیان ژن GFP به وسیله تداخل RNA (RNAi) در دودمان سلولی کارسینومای جنینی P19
Introduction: RNA interference (RNAi) is a phenomenon of gene silencing that uses double-stranded RNA (dsRNA), specifically inhibits gene expression by degrading mRNA efficiently. The mediators of degradation are 21- to 23-nt small interfering RNAs (siRNA). The use of siRNAs as inhibitors of gene expression has been shown to be an effective way of studying gene function in mammalian cells. Ai...
متن کاملViolet laser diodes in flow cytometry: an update.
INTRODUCTION In previous studies we and others have demonstrated the usefulness of violet laser diodes (VLDs) as replacement laser sources for krypton-ion lasers on stream-in-air cytometers. Previously available VLDs had a maximum available power of less than 25 mW; this was sufficient for excitation of densely labeled cell surface antigens using fluorochromes such as Cascade Blue or Pacific Bl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Cytometry. Part A : the journal of the International Society for Analytical Cytology
دوره 83 11 شماره
صفحات -
تاریخ انتشار 2013