Threshold ionic site concentrations required for Nernstian potentiometric responses of neutral ionophore-incorporated ion-selective liquid membranes.
نویسندگان
چکیده
An equation that can describe the concentrations of ionic sites required for a Nernstian potentiometric response slope of neutral ionophore-incorporated ion-selective liquid membranes is presented. This equation is derived from a model based on electrical diffuse layers on both the membrane and the aqueous sides of the interface, in which the phase boundary potential is correlated to the surface charge density as well as the salt concentrations in the bulk membrane and aqueous solution. To experimentally and accurately confirm the validity of this equation, response characteristics of field effect transistors covered by neutral ionophore-based liquid membranes with varying concentrations of a derivative of tetraphenylborate as an anionic site but free of ionic impurities were examined. The observed membrane potentials and the response slopes for membranes with various concentrations of anionic sites were in good agreement with the values calculated from the theory presented in this paper with the measured complexation stability constants for the relevant systems. This result indicates that the theoretical prediction based on the proposed equation for the anionic site concentration is accessible for the preparation of neutral ionophore-incorporated ion-selective liquid membranes, which show Nernstian response slopes for the primary ions.
منابع مشابه
Uultra-trace determination of cadmium (II) in aqueous environmental samples by a new ion selective electrode based on nefazodone and 1-butyl-3-methylimidazolium hexafluorophosphate ionic liquid
Background and Objective: Cadmium is a potential environmental contaminant that causes adverse effects on the environment and the health of living organisms. Therefore, designing a simple and economic technique for its determination is very important. In this respect, a potentiometric sensor based on nefazodone as the ionophore and [BMIM]PF6 as the ionic additive were developed for the determin...
متن کاملSpectroscopic method for the determination of the ionic site concentration in solvent polymeric membranes and membrane plasticizers.
The built-in site density of either fixed sites or mobile hydrophobic ion sites determines whether a membrane is permselective for cations or anions of the sample. The molar ratio of the ionophore to the intrinsic or added ionic sites in an ion-selective membrane significantly influences the potentiometric response of ionophore-based electrodes. Consequently, full knowledge of the "site invento...
متن کاملNovel ZrO2 ion-selective electrode based on 4,7,13,16,21,24-hexa oxa- 1,10- diazabicyc1o[8,8,8]-hexa cosane as neutral carrier in PVC matrix
In this work, a novel Zr02+ PVC-based membrane sensor based on 4,7,13,16,21,24-hexa oxa-1,10- diazabicyclo[8,8,8]- hexa cosane (HODBHC) as a new ionophore is presented. The sensor displays a linear dynamic rangebetween 1.0x 10-1 and 1.0x10 6 M, with a near Nernstian slope of 29.9 ± 0.4 mV per decade in an acidic solution(pH=1). The limit of detection is 8.0 x 1 0 7 M. The electrodes possess adv...
متن کاملAl(III) Coated Wire Selective Electrode Based on 5-Bromo(salicylidene-2-aminothiophenol) Schiff Base as a New Ionophore
A new Al(III) selective membrane based on 5-bromo(salicylidene-2-amino thiophenol) as a neutral carrier in a poly(vinyl chloride) (PVC) matrix is coated on platinum wire to determine trace amounts of Al(III) ion in various samples. The sensor exhibits a good response for Al(III) ion over a wide concentration range of 5.20 × 10-7 to 1.00 × 10-2 M with Nernstian slope of 19...
متن کاملDetermination of Strontium Ion in Depilatory Powder, Toothpaste, and Raticide Samples using a Novel and Highly Sensitive Potentiometric Sensor Coupled with a Central Composite Design
The strontium ion, in water-soluble forms, is one of the major pollutant in drinking water. Therefore, a simple, rapid, selective, and sensitive potentiometric carbon paste electrode was developed to measure strontium ion in real samples with complex matrices. To prepare the potentiometric sensor, a synthetic ligand ((E)-4-(((2-amino-4-chlorophenyl)imino)methyl)-5-(hydroxymethyl)-2-methyl pyrid...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 17 7 شماره
صفحات -
تاریخ انتشار 2001