On the diagnostic accuracy of stereotactic vacuum-assisted biopsy of nonpalpable breast abnormalities. Results in a consecutive series of 769 procedures performed at the Trento Department of Breast Diagnosis.
نویسندگان
چکیده
AIMS AND BACKGROUND To assess the diagnostic accuracy of stereotactic vacuum-assisted biopsy of nonpalpable breast lesions. METHODS AND STUDY DESIGN 769 consecutive vacuum-assisted biopsy procedures were retrospectively reviewed. Positive predictive value for carcinoma (B5) at vacuum-assisted biopsy was assessed on the overall series and by age, lesion morphology and size, degree of suspicion and calendar period. The accuracy of vacuum-assisted biopsy was based on surgical histology or follow-up (no change at 12 months was assumed as negative). RESULTS Lesions were depicted as isolated microcalcifications, opacity + microcalcifications, or opacity in 716 (93.1%), 28 (3.6%), or 25 (3.2%) cases, respectively. Vacuum-assisted biopsy was negative (B1 = 63; B2 = 319) in 382 (49.7%), borderline (B3) in 142 (18.5%), suspicious (B4) in 2 (0.3%), and positive (B5) in 243 (31.6%) cases (in situ = 185, 24.1%), invasive = 58 (7.5%)), respectively. Age (χ²df3 = 19.50; P <0.002), size (χ²df4 = 51.02; P = 10⁻⁶) and degree of suspicion (χ²df2 = 146.68; P = 10⁻⁶) were associated with a B5 outcome, no significant association was evident for morphology (χ²df2 = 0,47; P <0.78), whereas calendar period had a moderate but significant inverse association (χ²df2 = 6.12; P <0.04). The positive predictive value for surgically confirmed carcinoma (in situ or invasive) was 0% for B1, 0.7% for B2, 12.3% for B3, 100% for B4, 92.7% for in situ B5, and 94.6% for invasive B5. Conversion from in situ B5 to invasive was 12.3% and was insignificantly associated with size (χ²df2 = 0.95; P = 0.62) and histology grade (χ²df2 = 3.64; P = 0.16). Down-grading of vacuum-assisted biopsy lesions to a less severe histology occurred in 13 (7.2%) in situ and in 16 (28.6%) invasive carcinomas. B3 cases upgrading to more severe lesions was 0%, 4.5% or 16.0% in the presence of no, mild, or severe atypia. CONCLUSIONS The study confirmed a good performance of vacuum-assisted biopsy, possibly influenced by the local scenario (e.g., radiologist's and pathologist's interobserver variability and sampling modality). Conflicting results with the literature may have local explanations rather than being due to inadequate performance.
منابع مشابه
A comparison of spring-loaded and vacuum-assisted techniques for stereotactic breast biopsy of impalpable microcalcification lesions: experience at Chang Gung Memorial Hospital at Linkou.
BACKGROUND The aim of this study was to assess the diagnostic performance of stereotactic core needle breast biopsy using spring-loaded or vacuum-assisted techniques for impalpable microcalcification lesions in Taiwanese women. METHODS We retrospectively reviewed the data of patients who received stereotactic core needle breast biopsy for impalpable mammographic microcalcification lesions fro...
متن کاملVacuum-assisted stereotactic breast biopsy in the diagnosis and management of suspicious microcalcifications.
PURPOSE We aimed to present our biopsy method and retrospectively evaluate the results, upgrade rate, and follow-up findings of stereotactic vacuum-assisted breast biopsy (VABB) procedures performed in our clinic. METHODS Two hundred thirty-four patients with mammographically detected nonpalpable breast lesions underwent VABB using a 9 gauge biopsy probe and prone biopsy table. A total of 195...
متن کاملVacuum-assisted breast biopsy in nonpalpable solid breast lesions without microcalcifications: the Greek experience.
PURPOSE To present the initial Greek experience with vacuumassisted breast biopsy (VABB) in the diagnosis of nonpalpable solid mammographic lesions without microcalcifications. MATERIALS AND METHODS We performed 83 VABB procedures (using a Fischer table and 11-guage Mammotome probes) in an 18- month period on women with nonpalpable solid breast tumors. We performed VABB procedures on women wi...
متن کاملBreast microcalcifications: retrieval failure at prone stereotactic core and vacuum breast biopsy--frequency, causes, and outcome.
PURPOSE To retrospectively determine the frequency and causes of failure to retrieve microcalcifications in nonpalpable lesions, as judged on a radiograph of the specimen, and to determine outcome in patients with those lesions. MATERIALS AND METHODS Informed consent was obtained from each patient prior to biopsy. The institutional review board approved this HIPAA-compliant study and granted ...
متن کاملPercutaneous biopsy in radiological imaging of the breast
Radiol Bras. 2016 Mar/Abr;49(2):IX The article “Diagnostic underestimation of atypical hyperplasia and ductal carcinoma in situ at percutaneous core needle and vacuum-assisted biopsies of the breast in a Brazilian reference institution”, published in the previous issue of Radiologia Brasileira, was produced at a referral teaching institution and reflects the level of responsibility required in ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Tumori
دوره 98 1 شماره
صفحات -
تاریخ انتشار 2012