Effects of cryogen spray cooling and high radiant exposures on selective vascular injury during laser irradiation of human skin.
نویسندگان
چکیده
BACKGROUND Increasing radiant exposure offers a means to increase treatment efficacy during laser-mediated treatment of vascular lesions, such as port-wine stains; however, excessive radiant exposure decreases selective vascular injury due to increased heat generation within the epidermis and collateral damage to perivascular collagen. OBJECTIVE To determine if cryogen spray cooling could be used to maintain selective vascular injury (ie, prevent epidermal and perivascular collagen damage) when using high radiant exposures (16-30 J/cm2). DESIGN Observational study. SETTING Academic hospital and research laboratory. PATIENTS Twenty women with normal abdominal skin (skin phototypes I-VI). INTERVENTIONS Skin was irradiated with a pulsed dye laser (wavelength = 585 nm; pulse duration = 1.5 milliseconds; 5-mm-diameter spot) using various radiant exposures (8-30 J/cm2) without and with cryogen spray cooling (50- to 300-millisecond cryogen spurts). MAIN OUTCOME MEASURE Hematoxylin-eosin-stained histologic sections from each irradiated site were examined for the degree of epidermal damage, maximum depth of red blood cell coagulation, and percentage of vessels containing perivascular collagen coagulation. RESULTS Long cryogen spurt durations (>200 milliseconds) protected the epidermis in light-skinned individuals (skin phototypes I-IV) at the highest radiant exposure (30 J/cm2); however, epidermal protection could not be achieved in dark-skinned individuals (skin phototypes V-VI) even at the lowest radiant exposure (8 J/cm2). The red blood cell coagulation depth increased with increasing radiant exposure (to >2.5 mm for skin phototypes I-IV and to approximately 1.2 mm for skin phototypes V-VI). In addition, long cryogen spurt durations (>200 milliseconds) prevented perivascular collagen coagulation in all skin types. CONCLUSIONS Cryogen spurt durations much longer than those currently used in therapy (>200 milliseconds) may be clinically useful for protecting the epidermis and perivascular tissues when using high radiant exposures during cutaneous laser therapies. Additional studies are necessary to prove clinical safety of these protocols.
منابع مشابه
Optimum pulse duration and radiant exposure for vascular laser therapy of dark port-wine skin: a theoretical study.
Laser therapy for cutaneous hypervascular malformations such as port-wine stain birthmarks is currently not feasible for dark-skinned individuals. We study the effects of pulse duration, radiant exposure, and cryogen spray cooling (CSC) on the thermal response of skin, using a Monte Carlo based optical-thermal model. Thermal injury to the epidermis decreases with increasing pulse duration durin...
متن کاملExtent of lateral epidermal protection afforded by a cryogen spray against laser irradiation.
BACKGROUND AND OBJECTIVES Cryogen spray cooling (CSC) has become an integral part of dermatologic laser surgery because of its ability to remove selectively large amounts of heat from human skin in short periods of time, thereby protecting the epidermis from unintended thermal injury. The objective of the present study is to investigate the extent of lateral epidermal protection afforded by a c...
متن کاملEpidermal protection with cryogen spray cooling during high fluence pulsed dye laser irradiation: an ex vivo study.
BACKGROUND AND OBJECTIVE Higher laser fluences than currently used in therapy (5-10 J/cm(2)) are expected to result in more effective treatment of port wine stain (PWS) birthmarks. However, higher incident fluences increase the risk of epidermal damage caused by absorption of light by melanin. Cryogen spray cooling offers an effective method to reduce epidermal injury during laser irradiation. ...
متن کاملRadial Heat Transfer Dynamics during Cryogen Spray Cooling
Cryogen spray cooling (CSC) is a heat extraction process that protects the epidermal layer during skin laser surgery of port wine stain (PWS) birthmarks and other specific dermatoses. The objective of the present work is to investigate temporal and radial variations on the heat transferred at the surface of a skin model during CSC. A fast-response thermal sensor is used to measure temperature a...
متن کاملCorrelations between Spray Properties and Heat Transfer Dynamics during Cryogen Spray Cooling
INTRODUCTION Cryogen spray cooling (CSC) has been used along with pulsed lasers for nearly a decade to irreversibly photocoagulate a variety of vascular lesions. However, the fundamental mechanisms that take place at the skin surface are still incompletely understood. In this work, we built a fast-response temperature sensor with the objective to determine the time in which liquid cryogen remai...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archives of dermatology
دوره 139 6 شماره
صفحات -
تاریخ انتشار 2003