Technique for Dissection and Measurement of Refractive Index of Osteones

نویسندگان

  • Antonio Ascenzi
  • Claudine Fabry
چکیده

I t is known that a continuous process takes place in bone whereby mature osteones (Haversian systems) are broken down and new osteones are formed. Historadiographic study has shown that the mineral salts content of osteones increases gradually toward a maximum (1, 2, 8). In order to obtain information on the chemical and physical properties of the growing osteone, we have developed a dissection technique for isolating single osteone units.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modeling of measurement error in refractive index determination of fuel cell using neural network and genetic algorithm

Abstract: In this paper, a method for determination of refractive index in membrane of fuel cell on basis of three-longitudinal-mode laser heterodyne interferometer is presented. The optical path difference between the target and reference paths is fixed and phase shift is then calculated in terms of refractive index shift. The measurement accuracy of this system is limited by nonlinearity erro...

متن کامل

Measurement and comparison of the temperature-dependence of refractive index of water and Plexiglas phantoms by interferometry method for their use in optical calorimetry

In radiation calorimetry by using laser beams and interferometry setups, variations induced by dose absorption in phantom can be precisely measured. Dose absorption and the induced temperature change result in refractive index variation of the material. In order to be able to measure the low amount of absorbed dose in the phantom, temperature dependence of refractive index of the material must ...

متن کامل

Measurement of Thermophysical Properties of Pure and Mixture of Alkanolamines from 288.15-323.15 K

Density, viscosity and refractive index of pure, binary and ternary mixtures of diethanolamine (DEA) and methyl diethanolamine (MDEA) with water have been measured at different temperatures from 288.15 K to 323.15 K at atmospheric pressure. Also, this study presents the effects of mixture composition and temperature upon these thermo- physical properties. To measure the density and refractive i...

متن کامل

Measuring the temperature dependence of refractive index in water phantom for precise monitoring of the absorbed dose by radiation therapy techniques

In this paper, an experimental setup is used to measure the temperature dependence of the refractive index of a water phantom. In radiation calorimetry by laser beams and interferometric systems, the amount of change induced by radiation within the phantom can be accurately measured. Absorption of dose and the resulted change in temperature changes the refractive index within the material. In o...

متن کامل

Tip sensor probe for changing refractive index measurement in small volumes

In this paper, a tapered tip optical fiber probe sensor for localized refractive index (RI) measurements is presented. This sensor’s interaction with analytes is confined to a few micro-meters which makes it a promising candidate for in-vivo or even intra-cellular RI monitoring. This tapered tip was simply fabricated by etching optical fiber with hydrofluoric acid to a conic shape with a sub-m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of Biophysical and Biochemical Cytology

دوره 6  شماره 

صفحات  -

تاریخ انتشار 1959