Depth Correction for Depth Camera From Planarity
نویسندگان
چکیده
Depth cameras open new possibilities in fields such as 3D reconstruction, Augmented Reality and video-surveillance since they provide depth information at high frame-rates. However, like any sensor, they have limitations related to their technology. One of them is depth distortion. In this paper, we present a method to estimate depth correction for depth cameras. The proposed method is based on two steps. The first one is a nonplanarity correction that needs depth measurement of different plane views. The second one is an affinity correction that,contrary to state of the art approaches, requires a very small set of ground truth measurements. Thus, it is more easy to use compared to other methods and does not need a large set of accurate ground truth that is extremely difficult to obtain in practice. Experiments on both simulated and real data show that the proposed approach improve also the depth accuracy compare to state of the art methods.
منابع مشابه
Calibration of Depth Camera Arrays
Depth cameras are increasingly used for tasks such as 3-D reconstruction, user pose estimation, and humancomputer interaction. Depth-camera systems comprising multiple depth sensors require careful calibration. In addition to conventional 2-D camera calibration, depth correction for each individual device is necessary. In this paper, we present a new way of solving the multi depth-camera calibr...
متن کاملCamera Arrangement in Visual 3D Systems using Iso-disparity Model to Enhance Depth Estimation Accuracy
In this paper we address the problem of automatic arrangement of cameras in a 3D system to enhance the performance of depth acquisition procedure. Lacking ground truth or a priori information, a measure of uncertainty is required to assess the quality of reconstruction. The mathematical model of iso-disparity surfaces provides an efficient way to estimate the depth estimation uncertainty which ...
متن کاملDepth Correction for Depth Cameras From Planarity
Amira Belhedi123 [email protected] Adrien Bartoli2 http://isit.u-clermont1.fr/~ab/ Vincent Gay-Bellile1 [email protected] Steve Bourgeois1 [email protected] Patrick Sayd1 [email protected] Kamel Hamrouni3 [email protected] 1 CEA, LIST, LVIC, F-91191 Gif-sur-Yvette, France. 2 Clermont Université, Université d’Auvergne, ISIT, BP 10448, F63000 Clermont-Ferrand, France. ...
متن کاملA camera based calculation of 99mTc-MAG3 clearance using conjugate views method [Persian]
Background: Measurement of absolute or differential renal function using radiotracers plays an important role in the clinical management of various renal diseases. Gamma camera quantitative methods in approximation of renal clearance may potentially be as accurate as plasma clearance methods. However some critical factors such as kidney depth and background counts are still troublesome in...
متن کاملExperimental Evaluation of Depth Dose by Exit Surface Diode Dosimeters for Off-Axis Wedged Fields in Radiation Therapy
Introduction Evaluation of the delivered dose of externally wedged photon beams by external diode dosimeters during the treatment process requires the estimation of exit surface dose correction factors in various wedge angles and field sizes. Materials and Methods A system of absorbed dose evaluation, using p-type diode dosimeters placed on the exit surface of a phantom, was characterized for e...
متن کامل