Use of chest radiography in the initial evaluation of patients with localized melanoma.

نویسندگان

  • M H Terhune
  • N Swanson
  • T M Johnson
چکیده

OBJECTIVE To evaluate the use of an initial staging chest x-ray film in asymptomatic patients who present with localized primary cutaneous melanoma. DESIGN The staging workup of 1032 consecutive asymptomatic patients with localized melanoma was retrospectively reviewed via database chart review. SETTING Regional melanoma referral center in an academic medical center. PATIENTS The melanoma database identified 1032 asymptomatic patients with localized melanoma for retrospective review. Of the patients studied, 876 (85%) of 1032 had an initial staging chest x-ray film performed. A chest x-ray film was considered initial if performed within 6 months of melanoma diagnosis. MAIN OUTCOME MEASURE The rate of positive, negative, and suspicious findings of initial chest x-ray films. RESULTS One hundred thirty (15%) of 876 patients had suspicious findings necessitating additional workup. Based on follow-up radiologic findings, only 1 (0.1%) of 876 had a true-positive chest x-ray film demonstrating pulmonary metastasis. CONCLUSIONS The yield of detection of unsuspected pulmonary metastasis by chest x-ray film in the initial evaluation of asymptomatic patients with localized melanoma was exceedingly low (0.1%). Our results support the concept that routine chest radiograph screening in asymptomatic patients presenting with stage I and intermediate-thickness (1.5- to 4.0-mm) stage II melanoma is unlikely to yield true-positive findings of silent pulmonary metastasis. No definitive conclusions were drawn for the subset of patients with stage II thick melanoma (> 4.0 mm) because of the small number of patients (n = 40) in our series. Prospective studies are necessary to ultimately define the yield of initial radiographs in asymptomatic patients with localized melanoma.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dose Reduction to the Thyroid Gland in Pediatric Chest Radiography

Background  It is remain a main concern that pediatric chest radiographies contribute to the significant radiation exposure to the thyroid gland as a more susceptible organ to radiation induced cancer. The aim of this study was to evaluate the entrance surface dose (ESD) of pediatric chest radiography compared to the diagnostic reference levels (DRL) and evaluation the efficacy of the lead (Pb)...

متن کامل

Endobronchial Tuberculosis and Chest Radiography

Endobronchial tuberculosis and chest radiography I read, with interest, the article entitled “Clinical and Para-clinical Presentations of Endobronchial Tuberculosis” by Ahmadi Hoseini H. S. et al. (1) published in this journal. I would like to focus on some details about the chest X-ray of patients as elaborated by the authors in the results section. Accordingly, the findings of chest radiograp...

متن کامل

Dose Evaluation for Common Digital Radiographic Examinations in Selected Hospitals in Pahang Malaysia

Introduction: In digital radiography, radiographers tend to increase exposure factors to acquire an acceptable image quality thereby increasing radiation dose to patients.  Regarding this, the present study aimed to re-evaluate the exposure parameters and to ascertain the entrance surface dose (ESD) and effective dose (ED) of posterior-anterior (PA) chest, abdomen, and anterior-posterior (AP) l...

متن کامل

Evaluation of X-ray absorbed dose in thyroid during CXR imaging of the chest by Monte Carlo simulation (DOSXYZnrc)

Abstract:   Introduction: Chest radiography is one of the most common X-ray imaging procedures performed worldwide. During this process, in addition to the chest, other tissues, including the thyroid, are also exposed to radiation. Due to the fact that one of the most important risk factors for thyroid cancer is ionizing radiation, measuring the absorption of X- rays in the thyroid is of spec...

متن کامل

Survey of the Use of X-ray Beam Collimator and Shielding Tools during Infant Chest Radiography

Background The use of shielding tools and X-ray beam collimator has extensively been advocated as effective methods to reduce radiation exposure to patients underwent radiological procedures. The aim of this study was to address the use of these protection measures during infant chest radiography. Material and Methods 348digital and/or analogue infant chest radiographs were reviewed that perfor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of dermatology

دوره 134 5  شماره 

صفحات  -

تاریخ انتشار 1998