Representative Elementary Length to Measure Soil Mass Attenuation Coefficient

نویسندگان

  • J. A. R. Borges
  • L. F. Pires
  • J. C. Costa
چکیده

With increasing demand for better yield in agricultural areas, soil physical property representative measurements are more and more essential. Nuclear techniques such as computerized tomography (CT) and gamma-ray attenuation (GAT) have been widely employed with this purpose. The soil mass attenuation coefficient (μ(s)) is an important parameter for CT and GAT analysis. When experimentally determined (μ(es)), the use of suitable sized samples enable to evaluate it precisely, as well as to reduce measurement time and costs. This study investigated the representative elementary length (REL) of sandy and clayey soils for μ(es) measurements. Two radioactive sources were employed ((241)Am and (137)Cs), three collimators (2-4 mm diameters), and 14 thickness (x) samples (2-15 cm). Results indicated ideal thickness intervals of 12-15 and 2-4 cm for the sources (137)Cs and (241)Am, respectively. The application of such results in representative elementary area (REA) evaluations in clayey soil clods via CT indicated that μ(es) average values obtained for x > 4 cm and source (241)Am might induce to the use of samples which are not large enough for soil bulk density evaluations (ρ(s)). As a consequence, ρ(s) might be under- or overestimated, generating inaccurate conclusions about the physical quality of the soil under study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Low‐energy broad‐beam photon shielding data for constituents of concrete

The ability of concrete to attenuate ionizing radiation intensity is assessed using its linear or mass attenuation coefficient. In this work, the broad-beam linear and mass attenuation coefficients of different types of soils and cements used for making concrete were measured at different photon energies (60-1333 keV), nearly spanning the diagnostic photon energy range, using a NaI detector. Th...

متن کامل

Application of characteristic X-rays to measure linear attenuation coefficient of nano-composites used in shielding

Using of X-rays in different industries and especially in medical application is increasing. In this regard, designing of light and efficient protective material based on polymeric nanocomposites and precise study of the effect of adding nanoparticles with different sizes on the X-ray attenuation is necessary. In this study the epoxy nanocomposites with different percentages of copper oxide nan...

متن کامل

Investigation of the Mass Attenuation Coefficient for Composites Containing Nano and Micro-Particles of Copper Oxide against Diagnostic X-ray

Radiation protection and the selection of suitable materials to reduce radiation effects is one of the important branches of medical science and radiation. In this paper, the mass attenuation coefficients, half value layer thicknesses and thicknesses of 0/5 mm lead of polyvinyl chloride (PVC) composites containing Nano and micro-particles of copper oxide are calculated using experimental method...

متن کامل

Measurement of the x-ray mass attenuation coefficient and the imaginary part of the form factor of silicon using synchrotron radiation

We used the x-ray extended-range technique to measure the x-ray mass attenuation coefficients of silicon with an accuracy between 0.27% and 0.5% in the 5 keV220 keV energy range. Subtraction of the x-ray scattering contribution enabled us to derive the corresponding x-ray photoelectric absorption coefficients and determine the absolute value of the imaginary part of the atomic form factor of si...

متن کامل

Full-foil x-ray mapping of integrated column density applied to the absolute determination of mass attenuation coefficients

Recent measurements of mass attenuation coefficients have identified the determination of the thickness of the absorbing specimen as the major limitation to the accuracy of the measurement. We present a technique for determining the mass attenuation coefficient with high accuracy. The technique uses the integral of the density along a column extending through the thickness of the absorber, whic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2014  شماره 

صفحات  -

تاریخ انتشار 2014