Face and content validity of a virtual-reality simulator for myringotomy with tube placement

نویسندگان

  • Caiwen Huang
  • Horace Cheng
  • Yves Bureau
  • Sumit K. Agrawal
  • Hanif M. Ladak
چکیده

BACKGROUND Myringotomy with tube insertion can be challenging for junior Otolaryngology residents as it is one of the first microscopic procedures they encounter. The Western myringotomy simulator was developed to allow trainees to practice microscope positioning, myringotomy, and tube placement. This virtual-reality simulator is viewed in stereoscopic 3D, and a haptic device is used to manipulate the digital ear model and surgical tools. OBJECTIVE To assess the face and content validity of the Western myringotomy simulator. METHODS The myringotomy simulator was integrated with new modules to allow speculum placement, manipulation of an operative microscope, and insertion of the ventilation tube through a deformable tympanic membrane. A questionnaire was developed in consultation with instructing surgeons. Fourteen face validity questions focused on the anatomy of the ear, simulation of the operative microscope, appearance and movement of the surgical instruments, deformation and cutting of the eardrum, and myringotomy tube insertion. Six content validity questions focused on training potential on surgical tasks such as speculum placement, microscope positioning, tool navigation, ear anatomy, myringotomy creation and tube insertion. A total of 12 participants from the Department of Otolaryngology-Head and Neck Surgery were recruited for the study. Prior to completing the questionnaire, participants were oriented to the simulator and given unlimited time to practice until they were comfortable with all of its aspects. RESULTS Responses to 12 of the 14 questions on face validity were predominantly positive. One issue of concern was with contact modeling related to tube insertion into the eardrum, and the second was with the movement of the blade and forceps. The former could be resolved by using a higher resolution digital model for the eardrum to improve contact localization. The latter could be resolved by using a higher fidelity haptic device. With regard to content validity, 64% of the responses were positive, 21% were neutral, and 15% were negative. CONCLUSIONS The Western myringotomy simulator appears to have sufficient face and content validity. Further development with automated metrics and skills transference testing is planned.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Adenoidectomy and Myringot-omy with and without Tube Placement in the Short Term Hearing Status of Children with Otitis Media with Effusion: A Preliminary Re-port

Background: Otitis media with effusion (OME) is the most frequent indication for surgery in children. Some surgeons prefer to use adenoidectomy and myringotomy with tympanostomy tubes insertion to prevent the sequelae of the disease and also more improvement of hearing. The aim of this study is to compare adenoidectomy-myringotomy with adenoidectomy-myringotomy plus tympanostomy tube in the man...

متن کامل

Comparison of Adenoidectomy and Myringotomy with and without Tube Placement in the Short Term Hearing Status of Children with Otitis Media with Effusion: A Preliminary Report

Dear Editor, I read with enthusiasm the article entitled "Comparison of Adenoidectomy and Myringotomy with and without Tube Placement in the Short Term Hearing Status of Children with Otitis Media with Effusion" by Drs. Shishegar and Hoghoghi, which was published in IJMS 2007; 32:168-171. I think there are grave misconceptions and doubtful materials in the article. I also disagree with some of ...

متن کامل

Construct, Face, and Content Validation on Voxel-Man® Simulator for Otologic Surgical Training

Objective. To assess the face, content, and construct validity of the Voxel-Man TempoSurg Virtual Reality simulator. Participants and Methods. 74 ear, nose, and throat (ENT) surgeons participated. They were assigned to one of two groups according to their level of expertise: the expert group (n = 16) and the novice group (n = 58). The participants performed four temporal bone dissection tasks o...

متن کامل

Face, content and construct validity of the University of Washington virtual reality transurethral prostate resection trainer.

PURPOSE We examined the face, content and construct validity of version 1.0 of the University of Washington transurethral prostate resection (TURP) trainer. MATERIALS AND METHODS Version 1.0 of a virtual reality based simulator for transurethral skills was developed at our laboratory by integrating TURP hardware with our virtual 3-dimensional anatomy, irrigation control, cutting, bleeding and...

متن کامل

Head-to-Head Comparison of Three Virtual-Reality Robotic Surgery Simulators

Background and Objectives There are several different commercially available virtual-reality robotic simulators, but very little comparative data. We compared the face and content validity of 3 robotic surgery simulators and their pricing and availability. Methods Fifteen participants completed one task on each of the following: dV-Trainer (dVT; Mimic Technologies, Inc., Seattle, Washington, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 44  شماره 

صفحات  -

تاریخ انتشار 2015