Mitral annulus morphologic and functional analysis using real time tridimensional echocardiography in patients submitted to unsupported mitral valve repair

نویسندگان

  • Marco Antônio Vieira Guedes
  • Pablo Maria Alberto Pomerantzeff
  • Carlos Manuel de Almeida Brandão
  • Marcelo Luiz Campos Vieira
  • Flávio Tarasoutchi
  • Pablo da Cunha Spinola
  • Fábio Biscegli Jatene
چکیده

INTRODUCTION Mitral valve repair is the treatment of choice to correct mitral insufficiency, although the literature related to mitral valve annulus behavior after mitral repair without use of prosthetic rings is scarce. OBJECTIVE To analyze mitral annulus morphology and function using real time tridimensional echocardiography in individuals submitted to mitral valve repair with Double Teflon technique. METHODS Fourteen patients with mitral valve insufficiency secondary to mixomatous degeneration that were submitted to mitral valve repair with the Double Teflon technique were included. Thirteen patients were in FC III/IV. Patients were evaluated in preoperative period, immediate postoperative period, 6 months and 1 year after mitral repair. Statistical analysis was made by repeated measures ANOVA test and was considered statistically significant P<0.05. RESULTS There were no deaths, reoperation due to valve dysfunction, thromboembolism or endocarditis during the study. Posterior mitral annulus demonstrated a significant reduction in immediate postoperative period (P<0.001), remaining stable during the study, and presents a mean of reduction of 25.8% comparing with preoperative period. There was a significant reduction in anteroposterior and mediolateral diameters in the immediate postoperative period (P<0.001), although there was a significant increase in mediolateral diameter between immediate postoperative period and 1 year. There was no difference in mitral internal area variation over the cardiac cycle during the study. CONCLUSION Segmentar annuloplasty reduced the posterior component of mitral annulus, which remained stable in a 1-year-period. The variation in mitral annulus area during cardiac cycle remained stable during the study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mitral valve repair by Double Teflon technique: cardiac remodeling analysis by tridimensional echocardiography.

INTRODUCTION Mitral valve repair is the treatment of choice to correct mitral insufficiency. Although the literature related to left atrial and ventricular behavior after mitral repair without use of prosthetic rings is scarce. OBJECTIVE To analyze cardiac morphology and function using real time tridimensional echocardiography in individuals submitted to mitral valve repair with Double Teflon...

متن کامل

Right sided heart evaluation after successful mitral valve replacement.

Introduction: It is well-documented that right-sided heart dysfunction and significant tricuspid valve regurgitation (TVR) have adverse effects on patient outcomes after left-sided heart valve surgery. Therefore, the evaluation of right ventriclular (RV) function and TR severity in patients who had undergone mitral valve replacement (MVR), associated with/without concomitant su...

متن کامل

بررسی اختلالات قلبی در بیماران مبتلا به آرتریت روماتوئید بدون علائم بیماری قلبی، در بیمارستان قائم مشهد (87-1386)

  Background and Aim: Cardiovascular disorders are the most common cause of premature deaths in patients with rheumatoid arthritis (RA). This study dealt with echocardiographical findings in patients with rheumatoid arthritis.   Materials and Methods: Forty patients with established diagnosis of RA for more than five years, who lacked any known cardiovascular and brain symptoms, were enrolle...

متن کامل

Valvular Heart Disease Mitral Annular Dynamics in Myxomatous Valve Disease New Insights With Real-Time 3-Dimensional Echocardiography

Background—Mitral annulus is a complex structure of poorly understood physiology. Full-volume real-time 3-dimensional transesophageal echocardiography offers a unique opportunity to completely image and quantify mitral annulus size and motion. Methods and Results—Real-time 3-dimensional transesophageal echocardiography of the mitral valve was acquired in 32 patients with myxomatous valve diseas...

متن کامل

Role of real-time three-dimensional transesophageal echocardiography in mitral valve repair

Background and objective Pre-operative assessment of mitral valve (MV) anatomy is essential to surgical design in patients undergoing MV repair. Although 2-dimensional (2D) echocardiography provides precise information regarding MV anatomy, RT-3D TEE could increase the understanding of MV apparatus and individual scallop identification. We aimed to investigate the value of RT3DTEE in MV repair....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 30  شماره 

صفحات  -

تاریخ انتشار 2015