Insulin Adsorption to Catheter Materials Used for Intensive Insulin Therapy in Critically Ill Patients: Polyethylene Versus Polyurethane – Possible Cause of Variation in Glucose Control?

نویسندگان

  • Stephan Christoph Ley
  • Jan Ammann
  • Christian Herder
  • Thorsten Dickhaus
  • Matthias Hartmann
  • Detlef Kindgen-Milles
چکیده

Introduction: Restoring and maintaining normoglycemia by intensified insulin therapy in critically ill patients is a matter of ongoing debate since the risk of hypoglycemia may outweigh positive effects on morbidity and mortality. In this context, adsorption of insulin to different catheter materials may contribute to instability of glucose control. We studied the adsorption of insulin to different tubing materials in vitro and the effects on glycemic control in vivo. Materials and Methods: In vitro experiments: A syringe pump was filled with 50 IU insulin diluted to 50 ml saline. A flow of 2 ml/h was perfused through polyethylene (PET) or polyurethane (PUR) tubing. Insulin concentrations were measured at the end of the tube for 24 hours using Bradford ́s protein assay. In vivo study: In a randomized doubleblinded cross-over design, 10 intensive care patients received insulin via PET and PUR tubes for 24 hours each, targeting blood glucose levels of 80-150 mg/dl. We measured blood glucose levels, the insulin dose required to maintain target levels, and serum insulin and C-peptide levels. Results: In vitro experiments: After the start of the insulin infusion, only 20% (median, IQR 20-27) (PET) and 22% (IQR 16-27) (PUR) of the prepared insulin concentration were measured at the end of the 2 meter tubing. Using PET, after one hour infusion the concentration increased to 34% (IQR 29-36) and did not increase significantly during the next 24 hours (39% (IQR 39-40)). Using PUR, higher concentrations were detected than for PET at every measurement from 1 hour (82% (IQR 70-86)) to 24 hours (79% (IQR 64-87)). In vivo study: Glycemic control was effective and not different between groups. Significantly higher volumes of insulin solution had to be infused with PET compared to PUR (median PET 70.0 (IQR 56-82) ml vs. PUR 42 (IQR 31-63) ml; p=0.0015). Serum insulin concentrations did not decrease significantly one hour after changing to PET or PUR tubing. Conclusion: Polyurethane tubing systems allow application of insulin with significantly lower adsorption rates than polyethylene tubing systems. As a consequence, less insulin solution has to be infused to patients for effective blood glucose control. Tubing material of the insulin infusion may be crucial for safe and effective glycemic control in critically

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Metformin Treatment in Hyperglycemic Critically Ill Patients: Another Challenge on the Control of Adverse Outcomes

New-onset hyperglycemia in patients admitted to intensive care units increases the risk of morbidity and mortality. Insulin resistance is frequently seen in the treatment of stress-induced hyperglycemia. Metformin, an oral anti-hyperglycemic agent, may introduce a new treatment protocol in critically ill patients with insulin-resistance hyperglycemia. Fifty-one non-diabetic traumatized patients...

متن کامل

Metformin Treatment in Hyperglycemic Critically Ill Patients: Another Challenge on the Control of Adverse Outcomes

New-onset hyperglycemia in patients admitted to intensive care units increases the risk of morbidity and mortality. Insulin resistance is frequently seen in the treatment of stress-induced hyperglycemia. Metformin, an oral anti-hyperglycemic agent, may introduce a new treatment protocol in critically ill patients with insulin-resistance hyperglycemia. Fifty-one non-diabetic traumatized patients...

متن کامل

Microalbuminuria in Hyperglycemic Critically Ill Patients Treated with Insulin or Metformin

Microalbuminuria is thought to reflect the severity of inflammation-induced systemic vascular permeability. The present study investigated the effect of early administration of metformin or insulin on microalbuminuria in traumatized critically ill patients. Between April 2006 and October 2007, thirty-one non-diabetics traumatized patients with systemic inflammatory response syndrome (SIRS) and ...

متن کامل

Microalbuminuria in Hyperglycemic Critically Ill Patients Treated with Insulin or Metformin

Microalbuminuria is thought to reflect the severity of inflammation-induced systemic vascular permeability. The present study investigated the effect of early administration of metformin or insulin on microalbuminuria in traumatized critically ill patients. Between April 2006 and October 2007, thirty-one non-diabetics traumatized patients with systemic inflammatory response syndrome (SIRS) and ...

متن کامل

More Insulin to Control Glucose Levels May Not Be Better Intensive Versus Conventional Glucose Control in Critically Ill Patients

Background: Better glucose control has been linked to better outcomes and reduced infections in some patient populations. Fear of hypoglycemic complications continues, and some physicians have been slow to adopt strict glucose control for critically ill patients. Objective: To compare outcomes in critically ill patients when either tight or conventional glucose control is used. Design: Prospect...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014