Pulsed quantum cascade laser based hypertemporal real-time headspace measurements.

نویسندگان

  • Toby K Boyson
  • Dylan R Rittman
  • Thomas G Spence
  • Maria E Calzada
  • Abhijit G Kallapur
  • Ian R Petersen
  • K Paul Kirkbride
  • David S Moore
  • Charles C Harb
چکیده

Optical cavity enhancement is a highly desirable process to make sensitive direct-absorption spectroscopic measurements of unknown substances, such as explosives, illicit material, or other species of interest. This paper reports advancements in the development of real-time cavity ringdown spectroscopy over a wide-bandwidth, with the aim to make headspace measurements of molecules at trace levels. We report results of two pulsed quantum cascade systems operating between (1200 to 1320)cm(-1) and (1316 to 1613)cm(-1) that measure the headspace of nitromethane, acetonitrile, acetone, and nitroglycerin, where the spectra are obtained in less than four seconds and contain at least 150,000 spectral wavelength datapoints.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulsed quantum-cascade laser-based sensor for trace-gas detection of carbonyl sulfide.

Simultaneous exhaled carbonyl sulfide (OCS) and carbon dioxide concentration measurements in human breath are demonstrated with a compact pulsed quantum-cascade laser-based gas sensor. We achieved a noise-equivalent sensitivity (1sigma) of 1.2 parts per billion by measuring a well-isolated OCS P(11) absorption line in the v3 band at 2057.6 cm(-1) using an astigmatic Herriott cell of 36-m optica...

متن کامل

Quantum Cascade Laser-Based Photoacoustic Sensor for Trace Detection of Formaldehyde Gas

We report on the development of a photoacoustic sensor for the detection of formaldehyde (CH(2)O) using a thermoelectrically cooled distributed-feedback quantum cascade laser operating in pulsed mode at 5.6 μm. A resonant photoacoustic cell, equipped with four electret microphones, is excited in its first longitudinal mode at 1,380 Hz. The absorption line at 1,778.9 cm(-1) is selected for CH(2)...

متن کامل

New Method for Isotopic Ratio Measurements of Atmospheric Carbon Dioxide Using a 4.3 μm Pulsed Quantum Cascade Laser

We present a new approach to the measurement of stable isotopic ratios of carbon dioxide using a near room temperature pulsed quantum cascade laser and a spectral ratio method based upon dual multiple pass absorption cells. The spectral ratio method improves precision and accuracy by reducing sensitivity to variations in the laser tuning rate, power and line width. The laser is scanned across t...

متن کامل

Temperature Effect on THz Quantum Cascade Lasers

A simple semi-phenomenological model, which accurately predicts the dependence of thresholdcurrent for temperature of Resonant-phonon three well quantum cascade laser based on verticaltransitions is offered. We found that, the longitude optical phonon scattering of thermally excitedelectrons is the most important limiting factor for thermal performance of high frequency THz QCLs.In low frequenc...

متن کامل

Development of a compact quantum cascade laser spectrometer for field measurements of CO2 isotopes

We report the development of a field-deployable, pulsed quantum cascade laser spectrometer. The instrument is designed to measure the 13C/12C isotopic ratio in the CO2 released from volcanic vents. Specific CO2 and CO2 absorption lines were selected around 4.3 μm, where the P-branch of CO2 overlaps the R-branch of CO2 of the 0001–0000 vibrational transition. This particular selection makes the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics express

دوره 22 9  شماره 

صفحات  -

تاریخ انتشار 2014