Modification of a draw-over vaporizer for use with sevoflurane.

نویسندگان

  • T Payne
  • R Neighbour
  • R Eltringham
چکیده

BACKGROUND Draw-over anaesthesia is widely used throughout the developing world, in disaster areas and in military anaesthesia when the supply of pressurized oxygen is unreliable. To date, no draw-over vaporizer has been able to deliver sufficient concentrations of sevoflurane for use in inhalation induction of anaesthesia. A laboratory study to assess the performance of a new vaporizer (DDV2) to deliver sevoflurane in a wide range of situations is described. METHODS In this study, the concentration of sevoflurane delivered at different dial settings (1-4%) and at different temperatures (20-40°C) in a draw-over mode was measured. The concentration of sevoflurane delivered at different dial settings with continuous flow (6 and 8 litre min(-1)) at 20°C was measured. The maximum possible concentration of sevoflurane that can be delivered by the DDV2 was measured at a continuous flow rate of 8 litre min(-1) at 20, 30, and 40°C. RESULTS Concentrations of sevoflurane delivered in the draw-over mode were within 0.5% of dialled setting up to 30°C. Above this temperature, higher levels of vapour were delivered. With continuous flow, concentrations of sevoflurane at 20°C were within 0.5% of dialled setting and were stable throughout the duration of the experiment. On the 'induction' setting, concentrations of sevoflurane of between 6.4% and 10.1% could be delivered with continuous flow. CONCLUSIONS The modifications to the DDV2 allow stable concentrations of sevoflurane to be delivered in draw-over and continuous flow modes over a range of temperatures. With continuous flow, concentrations of sevoflurane sufficient for induction of anaesthesia can be achieved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sevoflurane Output in the Isoflurane/Halothane Diamedica Draw-over Vaporiser.

INTRODUCTION Draw-over anaesthesia remains an attractive option for conduct of anaesthesia in austere conditions. The Diamedica Draw-over Vaporiser (DDV) is a modern draw-over vaporiser and has separate models for isoflurane/halothane and sevoflurane. MATERIALS AND METHODS A laboratory study was done to measure sevoflurane output in an isoflurane/ halothane DDV. We did 3 series of experiments...

متن کامل

Pollution of ambient air by volatile anesthetics: a comparison of 4 anesthetic management techniques.

Long-term exposure to waste anesthetic gas (WAG) may lead to health problems. The purpose of this study was to compare WAG concentrations resulting from 4 combinations of fresh gas flow (FGF) and vaporizer settings during a simulated intravenous induction in which the anesthetic is deepened using a volatile anesthetic delivered via mask ventilation before intubation. By using a lung model, WAG ...

متن کامل

Analysis of the composition of 'original' and generic sevoflurane in routine use.

BACKGROUND Original sevoflurane (Sevofrane) contains a small amount of water, which can inhibit the production of hydrofluoric acid. Hydrofluoric acid is highly pungent, and sevoflurane that contains a high concentration of hydrofluoric acid is not suitable for volatile induction of anaesthesia. Recently, generic sevoflurane (Sevoness) has become available in some countries. The generic product...

متن کامل

A field-expedient Ohmeda Universal Portable Anesthesia Complete draw-over vaporizer setup.

The Ohmeda Universal Portable Anesthesia Complete (U-PAC) draw-over anesthetic system is active in the US Army inventory. It is standard equipment for Certified Registered Nurse Anesthetists assigned to US Army Forward Surgical Teams and Joint Special Operations Command. The purpose of this article is to describe a practical and field-expedient U-PAC draw-over vaporizer setup used during Operat...

متن کامل

Effect of N2O on sevoflurane vaporizer settings during minimal- and low-flow anesthesia.

BACKGROUND Uptake of a second gas of a delivered gas mixture decreases the amount of carrier gas and potent inhaled anesthetic leaving the circle system through the pop-off valve. The authors hypothesized that the vaporizer settings required to maintain constant end-expired sevoflurane concentration (Etsevo) during minimal-flow anesthesia (MFA, fresh gas flow of 0.5 l/min) or low-flow anesthesi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 108 5  شماره 

صفحات  -

تاریخ انتشار 2012