A High-Performance Fluorescence Immunoassay Based on the Relaxation of Quenching, Exemplified by Detection of Cardiac Troponin I
نویسندگان
چکیده
The intramolecular fluorescence self-quenching phenomenon is a major drawback in developing high-performance fluorometric biosensors which use common fluorophores as signal generators. We propose two strategies involving liberation of the fluorescent molecules by means of enzymatic fragmentation of protein or dehybridization of double-stranded DNA. In the former, bovine serum albumin (BSA) was coupled with the fluorescent BODIPY dye (Red BSA), and then immobilized on a solid surface. When the insolubilized Red BSA was treated with proteinase K (10 units/mL) for 30 min, the fluorescent signal was significantly increased (3.5-fold) compared to the untreated control. In the second case, fluorophore-tagged DNA probes were linked to gold nanoparticles by hybridization with capture DNA strands densely immobilized on the surface. The quenched fluorescence signal was recovered (3.7-fold) by thermal dehybridization, which was induced with light of a specific wavelength (e.g., 530 nm) for less than 1 min. We next applied the Red BSA self-quenching relaxation technique employing enzymatic fragmentation to a high-performance immunoassay of cardiac troponin I (cTnI) in a microtiter plate format. The detection limit was 0.19 ng/mL cTnI, and the fluorescent signal was enhanced approximately 4.1-fold compared with the conventional method of direct measurement of the fluorescent signal from a non-fragmented fluorophore-labeled antibody.
منابع مشابه
An Aptamer-based Biosensor for Troponin I Detection in Diagnosis of Myocardial Infarction
Background: Acute myocardial infarction (MI) accounts for one third of deaths. Cardiac troponin I (TnI) is a reliable biomarker of cardiac muscle tissue injury and is employed in the early diagnosis of MI.Objectives: In this study, a molecular method is introduced to early diagnosis of MI by rapid detection of TnI.Materials and Methods: The detection method was based on electrochemical aptasens...
متن کاملMultiplex Detection of B-Type Natriuretic Peptide, Cardiac Troponin I and C-Reactive Protein with Photonic Suspension Array
A novel photonic suspension array has been developed for multiplex immunoassay. The carriers of this array were silica colloidal crystal beads (SCCBs). The codes of these carriers have characteristic reflection peaks originating from their structural periodicity; therefore they do not suffer from fading, bleaching, quenching or chemical instability. In addition, the fluorescence background of S...
متن کاملFully automated ultrasensitive digital immunoassay for cardiac troponin I based on single molecule array technology.
BACKGROUND The association between increases in cardiac troponin and adverse cardiac outcomes is well established. There is a growing interest in exploring routine cardiac troponin monitoring as a potential early indicator of adverse heart health trends. Prognostic use of cardiac troponin measurements requires an assay with very high sensitivity and outstanding analytical performance. We report...
متن کاملHighly Sensitive FRET-Based Fluorescence Immunoassay for Detecting of Aflatoxin B1 Using Magnetic/Silica Core-Shell as a Signal Intensifier
Background: Recently, some new nanobiosensors using different nanoparticles or microarray systems for detection of mycotoxins have been designed . However, rapid, sensitive and early detection of aflatoxicosis would be very helpful to distinguish high-risk persons. Objectives: We report a highly sensitive competitive immunoassay using magnetic/silica core shell as a signal intensifier for the d...
متن کاملبررسی تروپونین I در بیماران هیپوتیروئید مراجعه کننده به درمانگاه غدد بیمارستان حضرت رسول اکرم(ص)، انیستیتو غدد داخلی و متابولیسم
Background: With increase in the age there is an increase in both the incidence of hypothyroidism and cardiovascular diseases. We wanted to see whether hypothyroidism caused false positivity in patients who did not have cardiovascular problems or not. In hypothyroid state, creatine kinase leaks into blood. Troponin I in small amount persists in Cytosolic pool (the same site of creatine kina...
متن کامل