Freehand 3-D Sonographic Measurement of the Superficial Femoral Artery

نویسندگان

  • Dennis Sandkühler
  • Christian Sobotta
  • Matthias Samsel
  • Heinrich M. Overhoff
چکیده

Visualization of vessels for diagnostics and intervention are usually done under fluoroscopic X-ray view using intravenous contrast agents, which has potential risks. To avoid this problem an ultrasoundbased approach was investigated. The definition of reproducible geometric measures is important for image guided navigated implantations. Such measures can benefit from geometric body which approximate the vessels. We addressed the problem of fitting cylindric bodies to datasets by using a robust technique based on rejection strategies for irrelevant points and data sets.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Case Report of Ruptured Superficial Femoral Artery Aneurysm

Single superficial femoral artery (SFA) aneurysm is rare and occurs in approximately 5 per 100,000 patients. Rupture is a rare complication in this aneurysm. In this case report, we present the diagnostic and therapeutic work up of a ruptured SFA aneurysm of the right lower limb in a 75-year-old diabetic man with ischemic heart disease. Pre-surgical diagnosis was through physical examination fi...

متن کامل

Pseudoaneurysm of femoral artery after catheterisation: treatment by a mechanical compression device guided by colour Doppler ultrasound.

BACKGROUND Femoral artery pseudoaneurysm is a significant complication in patients undergoing diagnostic or therapeutic catheterisation. First choice treatment for pseudoaneurysm is freehand ultrasound guided compression repair, which is time consuming and uncomfortable for the patient and operator. AIM To explore a mechanical compression device (FemoStop) as an alternative treatment for iatr...

متن کامل

PRACTICE OBSERVED Pseudoaneurysm of femoral artery after catheterisation: treatment by a mechanical compression device guided by colour Doppler ultrasound

Background—Femoral artery pseudoaneurysm is a significant complication in patients undergoing diagnostic or therapeutic catheterisation. First choice treatment for pseudoaneurysm is freehand ultrasound guided compression repair, which is time consuming and uncomfortable for the patient and operator. Aim—To explore a mechanical compression device (FemoStop) as an alternative treatment for iatrog...

متن کامل

Rare Vascular Anomalies in the Femoral Triangle During Varicose Vein Surgery

BACKGROUND We observed several cases of rare vascular anomalies within the femoral triangle during varicose vein operations. METHODS From among 2,093 patients who underwent stripping operations of the great saphenous vein between January 2002 and June 2016, 14 cases of rare vascular anomalies were enrolled in this study. RESULTS Twelve cases of femoral artery and vein transposition (0.57%),...

متن کامل

Obtaining a superficial femoral artery graft in adolescents and children with the deep femoral artery transposition.

A new technique to obtain a segment of the superficial femoral artery as an arterial conduit in young patients while an unobstructed peripheral blood flow is maintained by superficial femoral artery-deep femoral artery transposition is illustrated with two clinical examples. The explanted arterial autograft requires no replacement by another graft and provides a conduit of up to 10 cm in length...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008