Application of external-cavity quantum cascade infrared lasers to nanosecond time-resolved infrared spectroscopy of condensed-phase samples following pulse radiolysis.

نویسندگان

  • David C Grills
  • Andrew R Cook
  • Etsuko Fujita
  • Michael W George
  • Jack M Preses
  • James F Wishart
چکیده

Pulse radiolysis, utilizing short pulses of high-energy electrons from accelerators, is a powerful method for rapidly generating reduced or oxidized species and other free radicals in solution. Combined with fast time-resolved spectroscopic detection (typically in the ultraviolet/visible/near-infrared), it is invaluable for monitoring the reactivity of species subjected to radiolysis on timescales ranging from picoseconds to seconds. However, it is often difficult to identify the transient intermediates definitively due to a lack of structural information in the spectral bands. Time-resolved vibrational spectroscopy offers the structural specificity necessary for mechanistic investigations but has received only limited application in pulse radiolysis experiments. For example, time-resolved infrared (TRIR) spectroscopy has only been applied to a handful of gas-phase studies, limited mainly by several technical challenges. We have exploited recent developments in commercial external-cavity quantum cascade laser (EC-QCL) technology to construct a nanosecond TRIR apparatus that has allowed, for the first time, TRIR spectra to be recorded following pulse radiolysis of condensed-phase samples. Near single-shot sensitivity of DeltaOD <1 x 10(-3) has been achieved, with a response time of <20 ns. Using two continuous-wave EC-QCLs, the current apparatus covers a probe region from 1890-2084 cm(-1), and TRIR spectra are acquired on a point-by-point basis by recording transient absorption decay traces at specific IR wavelengths and combining these to generate spectral time slices. The utility of the apparatus has been demonstrated by monitoring the formation and decay of the one-electron reduced form of the CO(2) reduction catalyst, [Re(I)(bpy)(CO)(3)(CH(3)CN)](+), in acetonitrile with nanosecond time resolution following pulse radiolysis. Characteristic red-shifting of the nu(CO) IR bands confirmed that one-electron reduction of the complex took place. The availability of TRIR detection with high sensitivity opens up a wide range of mechanistic pulse radiolysis investigations that were previously difficult or impossible to perform with transient UV/visible detection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of nanosecond time-resolved infrared detection at the LEAF pulse radiolysis facility.

When coupled with transient absorption spectroscopy, pulse radiolysis, which utilizes high-energy electron pulses from an accelerator, is a powerful tool for investigating the kinetics and thermodynamics of a wide range of radiation-induced redox and electron transfer processes. The majority of these investigations detect transient species in the UV, visible, or near-IR spectral regions. Unfort...

متن کامل

Signal processing strategies for liquid phase sensors based on external cavity quantum cascade lasers

Software Control Experimental Setup Due to the spectral properties and the high emission power, Quantum Cascade Lasers (QCLs) are nowadays a powerful source for mid-infrared radiation. QCLs are available in various modifications concerning the laser type. Distributed Feedback-QCLs (DFB-QCLs) are ideally suited for spectroscopy of gases as they offer mode-hop free emission. However, they can be ...

متن کامل

TRIPLE Q: a three channel quantum cascade laser absorption spectrometer for fast multiple species concentration measurements.

A compact and transportable three channel quantum cascade laser system (TRIPLE Q) based on mid-infrared absorption spectroscopy has been developed for time-resolved plasma diagnostics. The TRIPLE Q spectrometer encompasses three independently controlled quantum cascade lasers (QCLs), which can be used for chemical sensing, particularly for gas phase analysis of plasmas. All three QCLs are opera...

متن کامل

Optically tunable long wavelength infrared quantum cascade laser operated at room temperature

Related Articles Mid-infrared-pumped, electrically driven terahertz quantum laser: Enhanced pumping efficiency and prevention of electric-field domains J. Appl. Phys. 113, 033103 (2013) How does external feedback cause AlGaAs-based diode lasers to degrade? Appl. Phys. Lett. 102, 023502 (2013) Large-area ultraviolet GaN-based photonic quasicrystal laser with high-efficiency green color emission ...

متن کامل

Frequency characterization of a swept- and fixed-wavelength external-cavity quantum cascade laser by use of a frequency comb.

The instantaneous optical frequency of an external-cavity quantum cascade laser (QCL) is characterized by comparison to a near-infrared frequency comb. Fluctuations in the instantaneous optical frequency are analyzed to determine the frequency-noise power spectral density for the external-cavity QCL both during fixed-wavelength and swept-wavelength operation. The noise performance of a near-inf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied spectroscopy

دوره 64 6  شماره 

صفحات  -

تاریخ انتشار 2010