Comparative Evaluation of Physical Surface Changes and Incidence of Separation in Rotary Nickel-Titanium Instruments: An in Vitro SEM Study

نویسندگان

  • Rudra Kaul
  • Riyaz Farooq
  • Vibhuti Kaul
  • Shafayat Ullah Khateeb
  • Aamir Rashid Purra
  • Roopali Mahajan
چکیده

INTRODUCTION The aim of the present study was to comparatively evaluate the physical surface changes and incidence of separation in rotary nickel-titanium (NiTi) instruments using scanning electron microscope (SEM). METHODS AND MATERIALS A total number of 210 freshly extracted human maxillary and mandibular first molars were selected and distributed between three groups. Three different systems of rotary NiTi instruments, namely ProFile (PF), RaCe (RC) and Twisted File (TF), were used to prepare the canals using crown-down technique. All instruments were evaluated by means of SEM with 500× and 1500× magnifications, at four different stages; before use, after preparation of 7 and 14 canals and after instrument separation. Photomicrographs were also taken. The data was analyzed using the Kruskal-Wallis test and the level of significance was set at 0.001. It was found that H (HAT matrix) was 15.316 with 2 degrees of freedom. Moreover the various groups were compared using the Student-Newman-Keuls test with P<0.05 and it was found that all groups were significantly different. RESULTS RC showed the maximum wear of the surface followed by TF (P<0.05). PF showed the minimum wear except for its tip. There was no correlation between electropolishing and file fracture. Insignificant difference was observed in the mean number of canals shaped by PF and TF before their separation. CONCLUSION Clinically, TF performance was superior, followed by PF then RC. RC fracture rate was the greatest after preparing the least number of canals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cyclic fatigue testing of three different rotary nickel titanium endodontic instruments in simulated curved canals - an in vitro sem analysis.

INTRODUCTION Instrument separation is a serious concern in endodontics. Stainless steel instruments usually deform before they separate whereas Nickel Titanium instruments do not show any sign of deformation. AIM of the present study was to compare the cyclic rotations needed to fracture three different rotary nickel titanium endodontic instruments namely Profile, K3 Endo, RaCe in simulated c...

متن کامل

A scanning electron microscopy evaluation of microfractures, deformation and separation in EndoSequence and Profile nickel-titanium rotary files using an extracted molar tooth model.

The development of microfractures in the EndoSequence nickel-titanium rotary (NTR) file (Brassler USA, Savannah, GA) and Profile NTR file was evaluated by using scanning electron microscopy (SEM). Seventy-three maxillary buccal roots and 53 mandibular mesial roots with an average canal curvature of 37 degrees were randomly assigned to one of three groups and prepared with 21-mm .06 taper NTR fi...

متن کامل

Do NiTi instruments show defects before separation? Defects caused by torsional fatigue in hand and rotary nickel-titanium (NiTi) instruments which lead to failure during clinical use.

AIMS Visual and microscopic evaluation of defects caused by torsional fatigue in hand and rotary nickel titanium (NiTi) instruments. MATERIALS AND METHODS Ninety-six NiTi greater taper instruments which were routinely used for root canal treatment only in anterior teeth were selected for the study. The files taken include ProTaper for hand use, ProTaper Rotary files and Endowave rotary files....

متن کامل

Evaluation of the Effect of an Experimental Herbal versus Fluoridated Mouthwash on Frictional Resistance and Surface Roughness between Orthodontic Brackets and Two Types of Archwire: In Vitro Study

Introduction: The present study aimed to evaluate an experimental herbal mouthwash, as compared to sodium fluoride mouthwash on the frictional resistance and surface roughness between brackets and two rectangular archwire types. Methods: A total of 60 premolar׳s brackets engaged with 0.019×0.025 archwires made of stainless steel and nickel-titanium alloys were used in this study. The samples we...

متن کامل

Comparative Evaluation of Dentinal Microcrack Incidence After Root Canal Preparation by BioRaCe and Edge Taper Platinum

Background and Aim: Preparation of root canal with rotary nickel-titanium (NiTi) instruments may potentially create microcracks that can lead to vertical root fracture. This study aimed to compare the incidence of crack formation by BioRaCe and Edge Taper Platinum systems in the mesiobuccal canals of extracted first mandibular molars. Materials and Methods: In this experimental study, 50 first...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -