Water Calorimetry: The Heat Defect
نویسندگان
چکیده
Domen developed a sealed water calorimeter at NIST to measure absorbed dose to water from ionizing radiation. This calorimeter exhibited anomalous behavior using water saturated with gas mixtures of H2 and O2. Using computer simulations of the radiolysis of water, we show that the observed behavior can be explained if, in the gas mixtures, the amount-of-substance of H2 and of O2 differed significantly from 50 %. We also report the results of simulations for other dilute aqueous solutions that are used for water calorimetry-pure water, air-saturated water, and H2-saturated water. The production of H2O2 was measured for these aqueous solutions and compared to simulations. The results indicate that water saturated with a gas mixture containing an amount-of-substance of H2 of 50 % and of O2 of 50 % is suitable for water calorimetry if the water is stirred and is in contact with a gas space of similar volume. H2-saturated water does not require a gas space but O2 contamination must be guarded against. The lack of a scavenger for OH radicals in "pure" water means that, depending on the water purity, some "pure" water might require a large priming dose to remove reactive impurities. The experimental and theoretical problems associated with air-saturated water and O2-saturated water in water calorimeters are discussed.
منابع مشابه
Water Calorimetry: A Correction to the Heat Defect Calculations
In a recent publication, we used a reaction model (model III) to calculate the heat defect for the irradiation of aqueous solutions with ionizing radiation at 21 °C. Subsequent work has revealed that the literature value used for one of the rate constants in the model was incorrect. A revised model (model IIIR) incorporates the correct rate constant for 21 °C. Versions of models III and IIIR we...
متن کاملMeasurement and comparison of the temperature-dependence of refractive index of water and Plexiglas phantoms by interferometry method for their use in optical calorimetry
In radiation calorimetry by using laser beams and interferometry setups, variations induced by dose absorption in phantom can be precisely measured. Dose absorption and the induced temperature change result in refractive index variation of the material. In order to be able to measure the low amount of absorbed dose in the phantom, temperature dependence of refractive index of the material must ...
متن کاملA human calorimeter for the direct and indirect measurement of 24 h energy expenditure.
1. A calorimeter for the continuous measurement of heat production and heat loss in the human subject, for at least 24 h, is described. The calorimeter operated on the heat-sink principle for direct calorimetry and an open-circuit system for indirect calorimetry. 2. Sensible heat loss was measured using a water-cooled heat exchanger, and the temperature of water entering the heat exchanger was ...
متن کاملCalorimetric studies of dissolution of hydroxypropyl methylcellulose E5 (HPMC E5) in water.
The interaction of water with polymers is important because it directly or indirectly affects various properties such as rheological and transport properties. In this study, the hydration/dissolution of a hydrophilic polymer was investigated by calorimetric techniques. Hydroxypropyl methylcellulose E5 (Methocel, HPMC E5) was used as the model polymer. A water-insoluble, hydrophobic polymer, eth...
متن کاملOn the Relation of Setting and Early-Age Strength Development to Porosity and Hydration in Cement-Based Materials.
Previous research has demonstrated a linear relationship between compressive strength (mortar cubes and concrete cylinders) and cumulative heat release normalized per unit volume of (mixing) water for a wide variety of cement-based mixtures at ages of 1 d and beyond. This paper utilizes concurrent ultrasonic reflection and calorimetry measurements to further explore this relationship from the t...
متن کامل