ORIGINAL COMMUNICATION Accuracy of eight-polar bioelectrical impedance analysis for the assessment of total and appendicular body composition in peritoneal dialysis patients

نویسندگان

  • G Medici
  • C Mussi
  • AL Fantuzzi
  • M Malavolti
  • A Albertazzi
  • G Bedogni
چکیده

Objective: To establish the accuracy of bioelectrical impedance analysis (BIA) for the assessment of total and appendicular body composition in peritoneal dialysis (PD) patients. Design: Cross-sectional study. Setting: University Nephrology Clinic. Subjects: In all, 20 PD patients and 77 healthy controls matched for gender, age and body mass index. Methods: Whole-body fat-free mass (FFM) and appendicular lean tissue mass (LTM) were measured by dual-energy X-ray absorptiometry. Resistance (R) of arms, trunk and legs was measured by eight-polar BIA at frequencies of 5, 50, 250 and 500 kHz. Whole-body resistance was calculated as the sum of R of arms, trunk and legs. The resistance index (RI) was calculated as the ratio between squared height and whole-body or segmental R. Results: RI at 500 kHz was the best predictor of FFM, LTMarm and LTMleg in both PD patients and controls. Equations developed on controls overestimated FFM and LTMarm and underestimated LTMleg when applied to PD patients. Specific equations were thus developed for PD patients. Using these equations, the percent root mean-squared errors of the estimate for PD patients vs controls were 5 vs 6% for FFM, 8 vs 8% for LTMarm and 7 vs 8% for LTMleg. Conclusion: Eight-polar BIA offers accurate estimates of total and appendicular body composition in PD patients, provided that population-specific equations are used. Sponsorship: University of Modena and Reggio Emilia. European Journal of Clinical Nutrition advance online publication, 1 June 2005; doi:10.1038/sj.ejcn.1602165

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cross-calibration of eight-polar bioelectrical impedance analysis versus dual-energy X-ray absorptiometry for the assessment of total and appendicular body composition in healthy subjects aged 21-82 years.

AIM To calibrate eight-polar bioelectrical impedance analysis (BIA) against dual-energy X-ray absorptiometry (DXA) for the assessment of total and appendicular body composition in healthy adults. RESEARCH DESIGN A cross-sectional study was carried out. SUBJECTS Sixty-eight females and 42 males aged 21-82 years participated in the study. METHODS Whole-body fat-free mass (FFM) and appendicu...

متن کامل

Application of bioelectrical impedance to clinical assessment of body composition in peritoneal dialysis.

Patients on peritoneal dialysis (PD) develop complex changes in body composition. These changes reflect hydration, nutrition, and body fat, all important elements reflecting patient well-being and efficacy of therapy that should be assessed and monitored as guides to patient management. They are all notoriously difficult to accurately measure in clinical practice and simultaneous abnormalities ...

متن کامل

Comparison of Muscle Mass, Total Body Water and Total Body Protein in Type II Diabetics with Healthy Matched Adults by Bioelectrical Impedance Analysis

Background: Bioelectrical impedance analysis (BIA) is a new and rapid technique to validate body composition. Several studies have used this technique to evaluate body compositions, such as muscle mass, in diabetic patients, but the results are very different. This may due the differences between diabetic patients and control group. Therefore, this study aimed to compare the muscle mass of diab...

متن کامل

Bioelectrical Impedance versus Body Mass Index for Predicting Body Composition Parameters in Sedentary Job Women

Objective: Nowadays the value of bioelectrical impedance analysis (BIA) in the estimation of body adiposity both on a clinical basis in the individual and epidemiologically in large populations is of great interest. The current study determine accuracy of BIA compared with body mass index (BMI) measurement for estimating body composition in a group of normal weight employee women with a sedenta...

متن کامل

Phase Angle Measurement in Healthy Human Subjects through Bio-Impedance Analysis

Objective(s)Bioelectrical impedance is the measure of impedance of the body. Impedance consists of electric resistance and reactance. Phase angle (PA) is the tan value of the ratio of reactance versus electric resistance. PA depends on cell membrane integrity and on body cell mass. There exists a correlation between PA values and body cell mass.The objective of this study was to compare the PA ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005