Multicenter trial of sentinel node biopsy for breast cancer using both technetium sulfur colloid and isosulfan blue dye.

نویسندگان

  • L Tafra
  • D R Lannin
  • M S Swanson
  • Van Eyk JJ
  • K M Verbanac
  • A N Chua
  • P C Ng
  • M S Edwards
  • B E Halliday
  • C A Henry
  • L M Sommers
  • C M Carman
  • M R Molin
  • J E Yurko
  • R R Perry
  • R Williams
چکیده

OBJECTIVE To determine the factors associated with false-negative results on sentinel node biopsy and sentinel node localization (identification rate) in patients with breast cancer enrolled in a multicenter trial using a combination technique of isosulfan blue with technetium sulfur colloid (Tc99). SUMMARY BACKGROUND DATA Sentinel node biopsy is a diagnostic test used to detect breast cancer metastases. To test the reliability of this method, a complete lymph node dissection must be performed to determine the false-negative rate. Single-institution series have reported excellent results, although one multicenter trial reported a false-negative rate as high as 29% using radioisotope alone. A multicenter trial was initiated to test combined use of Tc99 and isosulfan blue. METHODS Investigators (both private-practice and academic surgeons) were recruited after attending a course on the technique of sentinel node biopsy. No investigator participated in a learning trial before entering patients. Tc99 and isosulfan blue were injected into the peritumoral region. RESULTS Five hundred twenty-nine patients underwent 535 sentinel node biopsy procedures for an overall identification rate in finding a sentinel node of 87% and a false-negative rate of 13%. The identification rate increased and the false-negative rate decreased to 90% and 4.3%, respectively, after investigators had performed more than 30 cases. Univariate analysis of tumor showed the poorest success rate with older patients and inexperienced surgeons. Multivariate analysis identified both age and experience as independent predictors of failure. However, with older patients, inexperienced surgeons, and patients with five or more metastatic axillary nodes, the false-negative rate was consistently greater. CONCLUSIONS This multicenter trial, from both private practice and academic institutions, is an excellent indicator of the general utility of sentinel node biopsy. It establishes the factors that play an important role (patient age, surgical experience, tumor location) and those that are irrelevant (prior surgery, tumor size, Tc99 timing). This widens the applicability of the technique and identifies factors that require further investigation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of subareolar and periareolar injection techniques for breast sentinel lymph node biopsy.

HYPOTHESIS Subareolar or periareolar injection of radioactive technetium sulfur colloid is equivalent to other injection techniques for breast cancer sentinel lymph node (SLN) biopsy. DESIGN AND SETTING Prospective, multicenter clinical trial. PATIENTS A total of 3961 individuals with clinical stage I and II breast cancer. INTERVENTIONS All patients underwent attempted SLN biopsy followed...

متن کامل

Systemic anaphylaxis associated with intramammary isosulfan blue injection used for sentinel node detection under general anesthesia.

IDENTIFICATION of the sentinel lymph node, a marker for metastatic disease, is used increasingly for the surgical management of melanomas and tumors of the head and neck, breast, thyroid, and genitourinary and gastrointestinal tracts. Isosulfan blue (Lymphazurin; Ben Venue Laboratories, Bedford, OH) is the agent most commonly used, occasionally in conjunction with technetium sulfur colloid. All...

متن کامل

Sentinel node biopsy as an indicator for pelvic nodes dissection in early stage cervical cancer.

The purpose of this study was to investigate the feasibility of sentinel node frozen biopsy to minimize the extensive pelvic lymph nodes dissection in early stage cervical cancer patients on the basis that the risk of skip metastasis to the paraaortic area is negligible. Twenty-six patients with early stage cervical cancer were enrolled in this study. Technetium-99m colloid albumin (Tc(99m)) wa...

متن کامل

Sentinel lymph node biopsy for conjunctival malignant melanoma: surgical techniques

BACKGROUND The purpose of this report is to examine the viability and safety of preoperative lymphoscintigraphy and radio guided sentinel lymph node (SLN) biopsy for conjunctival melanoma, and to identify the best technique to perform this procedure. METHODS Three patients diagnosed with malignant melanoma of the conjunctiva underwent lymphoscintigraphy and SLN biopsy using a dual technique c...

متن کامل

Sentinel lymph node biopsy in breast cancer: review on various methodological approaches.

AIMS AND BACKGROUND Sentinel lymph node biopsy has been accepted as a standard procedure for early stage breast cancer. In this retrospective analysis, the results obtained with different methodological approaches using radiocolloid with or without blue dye were examined. METHODS A total of 158 sentinel lymph node biopsies were performed in 152 patients. Group A (85 patients) underwent lympha...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Annals of surgery

دوره 233 1  شماره 

صفحات  -

تاریخ انتشار 2001