The coronary pressure-flow determinants left ventricular compliance in dogs.
نویسندگان
چکیده
Displacement of the left ventricular diastolic pressure-dimension relationship (change in compliance) has been observed with alterations in coronary perfusion pressure. The relative contribution of coronary (myocardial) blood flow, as compared with the perfusion pressure at which flow occurs, was studied in 10 dogs during diastolic relaxation potassium arrest during cardiopulmonary bypass. The normalized left ventricular pressure-dimension relationships, obtained during passive, gradual filling of the left ventricle (0-20 mm Hg) were shifted progressively to the left as coronary perfusion pressure was increased. Myocardial blood flow was 0.06 ml/mg per min +/- 0.02 ml/mg per min (mean +/- SEM) at a coronary perfusion pressure of 40 mm Hg and increased to 0.38 ml/mg per min +/- 0.11 ml/mg per min as the coronary perfusion pressure was raised to 120 mm Hg. Addition of adenosine significantly increased myocardial blood flow by 109% at a coronary perfusion pressure of 80 and by 147% at a coronary perfusion pressure of 120 mm Hg, but caused no additional significant shifts in the pressure-dimension relationships, compared to the same coronary perfusion pressures without adenosine. Coronary perfusion pressure, and not coronary blood flow, is a more direct determinant of cardiac diastolic properties.
منابع مشابه
The Coronary Pressure-Flow Determinants of Left Ventricular Compliance in Dogs
Displacement of the left ventricular diastolic pressure-dimension relationship (change in compliance) has been observed with alterations in coronary perfusion pressure. The relative contribution of coronary (myocardial) blood flow, as compared with the perfusion pressure at which flow occurs, was studied in 10 dogs during diastolic relaxation by potassium arrest during cardiopulmonary bypass. T...
متن کاملPhasic right coronary artery blood flow in conscious dogs with normal and elevated right ventricular pressures.
We studied phasic right coronary blood flow in well trained normal dogs and dogs with pulmonic stenosis. We installed electromagnetic flow transducers and pressure tubes under anesthesia to monitor right coronary blood flow, cardiac output, central aortic blood pressure, and right ventribular pressure. In normotensive dogs, systolic flow amplitude equaled early diastolic flow levels. The ratio ...
متن کاملAcute alterations in left ventricular diastolic chamber stiffness. Role of the "erectile" effect of coronary arterial pressure and flow in normal and damaged hearts.
To separate the effects of coronary flow, perfusion pressure, and oxygen delivery on left ventricular diastolic compliance and diastolic wall thickness, isolated buffer and blood-perfused rabbit hearts with left ventricular volume controlled by a fluid-filled intraventricular balloon were subjected to the following interventions: complete global ischemia, hypoxia at constant coronary flow, hypo...
متن کاملCoronary hypertension and diastolic compliance in isolated rabbit hearts.
Acute pulmonary edema during hypertensive crisis has been attributed to acute left ventricular systolic failure secondary to increased afterload. We tested the hypothesis that the increase in coronary artery perfusion pressure associated with systemic hypertension could also contribute to increased left ventricular filling pressures by acutely increasing coronary intravascular volume and decrea...
متن کاملEpicardial coronary artery compliance in the dog.
The dynamic compliance of 21 coronary arteries from 17 dogs was determined in situ. Intramyocardial portion* were occluded with a mixture of 200(1 glass beads and liquid silicone. To simulate in vivo pressure-volume conditions, 0.1 ml of saline was injected in 150 to 240 msec at a rate of 30 pulses/min. Silicone casts of the vessels, made at 100 mm Hg distending pressure, were used as a referen...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation research
دوره 49 4 شماره
صفحات -
تاریخ انتشار 1981