A new methodology for the in vivo estimation of the elastic constants that characterize the patient-specific biomechanical behavior of the human cornea.
نویسندگان
چکیده
This work presents a methodology for the in vivo characterization of the complete biomechanical behavior of the human cornea of each patient. Specifically, the elastic constants of a hyperelastic, second-order Ogden model were estimated for 24 corneas corresponding to 12 patients. The finite element method was applied to simulate the deformation of human corneas due to non-contact tonometry, and an iterative search controlled by a genetic heuristic was used to estimate the elastic parameters that most closely approximates the simulated deformation to the real one. The results from a synthetic experiment showed that these parameters can be estimated with an error of about 5%. The results of 24 in vivo corneas showed an overlap of about 90% between simulation and real deformed cornea and a modified Hausdorff distance of 25 μm, which indicates the great accuracy of the proposed methodology.
منابع مشابه
Loratadine- Loaded Thermoresponsive Hydogel : Characterization and Ex-vivo Rabbit Cornea Permeability Studies
Poor bioavailability of ophthalmic drops is mainly due to drainage through the nasal-lacrimal duct and a very low permeability through corneal epithelium. The aim of our study was to prepare and characterize an ocular hydrogel of loratadine, as an example of a lipophilic drug, to increase drug concentration and residence time at the site of action in the eye. In this study,a 23full factorial de...
متن کاملLoratadine- Loaded Thermoresponsive Hydogel : Characterization and Ex-vivo Rabbit Cornea Permeability Studies
Poor bioavailability of ophthalmic drops is mainly due to drainage through the nasal-lacrimal duct and a very low permeability through corneal epithelium. The aim of our study was to prepare and characterize an ocular hydrogel of loratadine, as an example of a lipophilic drug, to increase drug concentration and residence time at the site of action in the eye. In this study,a 23full factorial de...
متن کاملElastic constants and their variation by pressure in the cubic PbTiO3 compound using IRelast computational package within the density functional theory
p.p1 {margin: 0.0px 0.0px 0.0px 0.0px; text-align: justify; font: 12.0px 'Times New Roman'} span.s1 {font: 12.0px 'B Nazanin'} p.p1 {margin: 0.0px 0.0px 0.0px 0.0px; text-align: justify; font: 12.0px 'Times New Roman'} span.s1 {font: 12.0px 'B Nazanin'} In this paper, we study the structural and electronic properties of the cubic PbTiO3 compound by using the density functional the...
متن کاملتخمین غیرتهاجمی مدول الاستیک چشم کاتاراکته شده خرگوش
Although cataract is very common and its detection seems apparently easy especially in the mature cataract, its quantitative description to determine the critical value of diagnosis is too difficult. Non-invasive evaluation of the mechanical properties of eye is hampered by the absence of in-vivo methods for direct assessment of the axial length of eye, lens and cornea. In the present study...
متن کاملA Biomechanical Approach for the Study of Deformation of Red Cells in Narrow Capillaries
This model focuses on the behavior of capillary-tissue fluid exchange system when the diameter of the capillary is less than that of red cell. In vivo and in vitro observations indicate that the width of the gap between the red cell and the vessel wall is generally small compared to the radius of the capillary for a single file flow of red cell in narrow vessel, particularly if the vessel diame...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomechanics
دوره 48 1 شماره
صفحات -
تاریخ انتشار 2015