Seven direct methods for measuring HDL and LDL cholesterol compared with ultracentrifugation reference measurement procedures.
نویسندگان
چکیده
BACKGROUND Methods from 7 manufacturers and 1 distributor for directly measuring HDL cholesterol (C) and LDL-C were evaluated for imprecision, trueness, total error, and specificity in nonfrozen serum samples. METHODS We performed each direct method according to the manufacturer's instructions, using a Roche/Hitachi 917 analyzer, and compared the results with those obtained with reference measurement procedures for HDL-C and LDL-C. Imprecision was estimated for 35 runs performed with frozen pooled serum specimens and triplicate measurements on each individual sample. Sera from 37 individuals without disease and 138 with disease (primarily dyslipidemic and cardiovascular) were measured by each method. Trueness and total error were evaluated from the difference between the direct methods and reference measurement procedures. Specificity was evaluated from the dispersion in differences observed. RESULTS Imprecision data based on 4 frozen serum pools showed total CVs <3.7% for HDL-C and <4.4% for LDL-C. Bias for the nondiseased group ranged from -5.4% to 4.8% for HDL-C and from -6.8% to 1.1% for LDL-C, and for the diseased group from -8.6% to 8.8% for HDL-C and from -11.8% to 4.1% for LDL-C. Total error for the nondiseased group ranged from -13.4% to 13.6% for HDL-C and from -13.3% to 13.5% for LDL-C, and for the diseased group from -19.8% to 36.3% for HDL-C and from -26.6% to 31.9% for LDL-C. CONCLUSIONS Six of 8 HDL-C and 5 of 8 LDL-C direct methods met the National Cholesterol Education Program total error goals for nondiseased individuals. All the methods failed to meet these goals for diseased individuals, however, because of lack of specificity toward abnormal lipoproteins.
منابع مشابه
Comparison of a homogeneous assay with a precipitation method for the measurement of HDL cholesterol in diabetic patients.
OBJECTIVE To compare direct-measured HDL cholesterol with HDL cholesterol measured by a precipitation method. RESEARCH DESIGN AND METHODS We compared a homogeneous assay for direct HDL cholesterol analysis with the phosphotungstic acid magnesium chloride precipitation method in 55 type 1 diabetic patients, 70 type 2 diabetic patients, and 82 nondiabetic normal control subjects with plasma tri...
متن کاملQuantification of lipoprotein subclasses by proton nuclear magnetic resonance-based partial least-squares regression models.
BACKGROUND Cardiovascular disease risk can be estimated in part on the basis of the plasma lipoprotein profile. Analysis of lipoprotein subclasses improves the risk evaluation, but the traditional methods are very time-consuming. Novel, rapid, and productive methods are therefore needed. METHODS We obtained plasma samples from 103 fasting people and determined the plasma lipoprotein subclass ...
متن کامل(UC), isolation of HDL by precipitation of apolipoprotein B (apoB)-containing lipoproteins from the UC bottom fraction, and cholesterol analysis of the bottom fraction and the HDL supernatant by the CDC cholesterol refer-
Journal of Lipid Research Volume 52, 2011 383 Copyright © 2011 by the American Society for Biochemistry and Molecular Biology, Inc. for achieving a uniform interpretation of clinical data, which is essential for the prevention and management of CVD. Homogeneous methods have been widely used to directly measure LDL-C and HDL-C without pretreatment of specimens to separate the lipoproteins. Despi...
متن کاملComparison of LDL- Cholesterol Enzymatic Method with Friedewald’s Formula
Abstract Background and Objectives: Concentration low-density lipoprotein (LDL) is one of the strongest indicators of atherosclerosis and predicts the diagnosis of cardiovascular diseases. LDL measurement accuracy is very important. LDL can be measured directly, such as enzymatic and nephelometry methods or can be calculated using Friedewald...
متن کاملA micro-enzymatic method to measure cholesterol and triglyceride in lipoprotein subfractions separated by density gradient ultracentrifugation
A micro-enzymatic method was developed to measure total cholesterol (CHOL) and triglyceride (TG) in lipoproteins and their subfractions separated by density gradient ultracentrifugation. This method had a detection limit and sensitivity below 2 mg/dl and accuracy (bias to reference sera) and imprecision (coefficient of variation) of less than 3% between 2 and 30 mg/dl for both CHOL and TG. In a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 56 6 شماره
صفحات -
تاریخ انتشار 2010