R&d towards a Delta-type Undulator for the Lcls*
نویسندگان
چکیده
The LCLS generates linearly polarized, intense, high brightness x-ray pulses from planar fixed-gap undulators. While the fixed-gap design supports a very successful and tightly controlled alignment concept, it provides only limited taper capability (up to 1% through canted pole and horizontal position adjustability) and lacks polarization control. The latter is of great importance for soft x-ray experiments. A new compact out-of-vacuum undulator design (Delta), based on a 30-cm-long in-vacuum prototype at Cornell University, is being developed and tested to add those missing properties to the LCLS undulator line. Tuning Delta undulators within tight, FEL type tolerances is a challenge due to the fact that the magnetic axis and the magnet blocks are not easily accessible for measurements and tuning in the fully assembled state. An R&D project is underway to install a 3.2-m long out-of-vacuum device in place of the last LCLS undulator, to provide controllable levels of polarized radiation and to develop measurement and tuning techniques to achieve x-ray FEL type tolerances. Presently, the installation of the device is scheduled for August 2014.
منابع مشابه
Linac Coherent Light Source Undulator Rf Bpm System *
The Linac Coherent Light Source (LCLS) will be the world's first x-ray free-electron laser (FEL) when it becomes operational in 2009. The LCLS is currently in the construction phase. The beam position monitor (BPM) system planned for the LCLS undulator will incorporate a high-resolution X-band cavity BPM system described in this paper. The BPM system will provide high-resolution measurements of...
متن کاملA Plan for the Development of Superconducting Undulator Prototypes for Lcls-ii and Future Fels
Undulators serve as the primary source of radiation for modern storage rings, and more recently for the advent of Free-Electron Lasers (FELs). The performance of future FELs can be greatly enhanced using the much higher magnetic fields of superconducting undulators (SCU) [1]. For example, the LCLS-II hard x-ray undulator can be shortened by up to 70 m using an SCU in place of a PMU (permanent m...
متن کاملUndulator K-Parameter Measurements at LCLS
We report our first in-situ measurements of relative undulator segment K-parameters made at the LCLS. The diagnostics, calibration, procedure, and early results are described. Measurement errors and noise are discussed and the outlook for near-term develop presented.
متن کاملCoherent Radiation Effects in the Lcls Undulator∗
For X-ray Free-Electron Lasers such as LCLS and TESLA FEL, a change in the electron energy while amplifying the FEL radiation can shift the resonance condition out of the bandwidth of the FEL. The largest sources of energy loss is the emission of incoherent undulator radiation. Because the loss per electron depends only on the undulator parameters and the beam energy, which are fixed for a give...
متن کاملFirst Results of the Lcls Laser-heater System*
The very bright electron beam required for an x-ray freeelectron laser (FEL), such as the LCLS, is susceptible to a microbunching instability in the magnetic bunch compressors, prior to the FEL undulator. The uncorrelated electron energy spread in the LCLS can be increased by an order of magnitude to provide strong Landau damping against the instability without degrading the FEL performance. To...