Determination of peak expiratory flow.
نویسندگان
چکیده
It is still unknown whether peak expiratory flow (PEF) is determined by "wave speed" flow limitation in the airways. To investigate the influences of airway mechanical properties on PEF, five healthy adults performed maximal forced expiratory effort (MFEE) manoeuvres, in the standard manner and following breathholds at total lung capacity (TLC) of 2 s and 10 s. Oesophageal pressure (Poes) was measured as an index of respiratory effort. Subjects also performed a MFEE following a 10 s breathhold during which intrathoracic pressure was voluntarily raised by a Valsalva manoeuvre, which would increase transmural pressure and cross-sectional area of the extrathoracic airway. Additional MFEEs were performed with the neck fully flexed and extended, to change longitudinal tracheal tension. In separate studies, PEF was measured with a spirometer and with a pneumotachograph. Breathholds at TLC (2 s and 10 s), and neck flexion reduced PEF by a mean of 9.8% (SD 2.9%), 9.6% (SD 1.6%), and 8.7% (SD 2.8%), respectively, when measured with the spirometer. The same pattern of results was seen when measured with the pneumotachograph. These reductions occurred despite similar respiratory effort. Voluntarily raising intrathoracic pressure during a 10 s breathhold did not reverse a fall in PEF. MFEE manoeuvre with neck extension did not result in an increase in PEF, the group mean % changes being -3.0% (SD 5.0%). We conclude that these results do not allow the hypothesis that "wave-speed" (Vws) is reached at PEF to be rejected. A breathhold at TLC could increase airway wall compliance by allowing stress-relaxation of the airway, thus reducing the "Vws" achievable.
منابع مشابه
Peak Expiratory Flow Rate in Healthy Children from Tehran
Background: Measuring peak expiratory flow rate has been suggested as an important tool in asthma management by all international guidelines. Objective: Studies on various populations have shown considerable variations in normal values of peak expiratory flow rate. Since reference standards for Iranian children are not available, the present study was performed to establish these standards. Me...
متن کاملNormal measurement of peak expiratory Flow rate in the high school children in Babol, north of Iran
Background: Peak Expiratory Flow Rate (PEFR) is recommended as a tool for control of asthma. The purpose of this study was to determine the normal value of PEFR in the healthy high school children in Babol, Iran. Methods: This study was conducted on 470 healthy high school children (285 girls, 185 boys with the age between 14-18 years). For the determination of PEFR we used Mini Wright Peak Flo...
متن کاملبررسی تاثیر 1،6 هگزامتیلن دی ایزوسیا نات بر نتایج تست پیک فلومتری در کارگران کارگاههای رنگ کاری اتومبیل شهر اصفهان
Abstract Background & Aims: Hexamethylene diisocyanate is an aliphatic isocyanate and car painters are exposed to it. One of the most important disorders is occupational asthma. The aim of this study was to survey the effect of 1, 6 hexamethylene diisocyanate on the peak expiratory flow test to car painters in Isfahan. Materials & Methods: In this descriptive and a cross-sectional study the f...
متن کاملEffects of Ramadan fasting on spirometric values and clinical symptoms in asthmatic patients
Introduction: Ramadan is the 9th Islamic lunar month during which Muslims avoid eating and drinking from sunrise to sunset. The effect of Ramadan intermittent fasting on asthma control is controversial. The aim of this study was to investigate the effects of Ramadan fasting on the spirometric variables and clinical symptoms on well-controlled asthmatic patients during Ramadan. Material and M...
متن کاملPulmonary function in Parkinson's disease.
Pulmonary function was investigated in 31 consecutive patients with relatively severe Parkinson's disease. Clinical disability was assessed by Hoehn and Yahr scale, Northwestern University Disability Scale and Websterscore. All patients were on levodopa substitution therapy and used anticholinergics. Pulmonary function was investigated by spirography, determination of a maximal inspiratory and ...
متن کاملComparison of Effects of Flutter Device versus Autogenic Drainage on Peak Expiratory Flow Rate, Oxygen Saturation, Respiratory Rate and Pulse Rate in COPD Patients
In an earlier comparative study reported between Flutter device and Autogenic Drainage, Skaria et al. [5], found that Flutter device is more effective than the forced expiratory technique i.e. Autogenic Drainage. They reported greater improvement in terms of oxygen saturation and peak expiratory flow rate in the patients of moderate chronic bronchitis, who had used Flutter device. Ernst et al. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The European respiratory journal
دوره 6 9 شماره
صفحات -
تاریخ انتشار 1993