Performance and Reliability Degradation of a Residential Unitary Air Conditioning System Resulting from a Mismatch of a 1992 Air Conditioning Unit with a 15-20 Year Old Evaporator
نویسندگان
چکیده
Fred Keller Split Systems Director The National Appliance Energy Conservation Act has established a minimum efficiency of 10 SEER for residential split system air conditioners and heat pumps. Approximately 50% of residential split system air conditioners are sold as replacements for units having much lower SEER levels, typically 5-9 Btu/W·h. This investigation assessed the detrimental affects that could occur when a 1992 vintage 10 SEER air conditioner is used to replace a 15-20 year old outdoor unit without replacing the indoor evaporator section. An evaporator constructed with similar geometry as a 15 year old, 30,000 Btu/h (8,790 W) evaporator was tested with a typical 1992, 10 SEER residential air conditioner. The performance of the 1992 outdoor unit with the old evaporator experienced 5% degradation in capacity and 11% degradation in SEER. The system also operated at compression ratios typically 20% higher than the system with the properly sized evaporator; thus increasing the stresses on the compressor and hence reducing its life. INTRODUCTION The National Appliance Energy Conservation Act has mandated that all residential split system (central) air conditioners and heat pumps built on or after January 1, 1992 have seasonal efficiencies of at least 10 SEER. This is a substantial increase from older systems which typically operated between 5 and 9 SEER. By redesigning the three primary components of the system, the compressor, condenser, and evaporator, manufacturers are able to attain minimum efficiency standards. Although manufacturers focus on capacity and SEER while designing new air conditioners and heat pumps, they are also very aware of design parameters which influence the reliability of their systems. Product and more specifically, compressor reliability is highly dependent upon the proper design and installation of the air conditioning system. Historically, nearly one-half of first year residential split system component failures are compressors. Primary causes of these failures include: (1) liquid entrainment in the suction gas during start-up (slugging), (2) liquid entrainment in the suction gas during steady-state operation (flooding), (3) excessive cycling, ( 4) oil starvation and dilution, (5) operation at excessive compression ratios, and (6) overheating.
منابع مشابه
Thermal modeling of mini-channel and laminated Types evaporator in mobile air conditioning system
In this paper, mini-channel type evaporator which is new in mobile air conditioning (MAC) or automotive air conditioning (AAC) systems is thermally modeled. The performance of mini-channel evaporator is also compared with the laminated evaporator which is being currently used in automotive industries. The mini-channel evaporator was constructed of two rows of parallel flow mini-channel tubes...
متن کاملPassive Energy Air-to-Water Heat Pipe Based Heat Exchanger and its Potential of Air Pre-cooling in Air Conditioning Systems for Iran Climate
Air pre-cooling equipment is normally being employed in air-conditioning systems for pre-cooling the ambient outdoor air to enhance the air-conditioning systems performance. In this study, the potential of a passive water-to-air heat pipe based heat exchanger (HPHEX) for air pre-cooling purpose in air-conditioning systems for the high cooling load demanding regions of Iran was investigated. To ...
متن کاملDesign and operation optimization of an air conditioning system through simulation: an hour-by-hour simulation study
In the present research, performance validation of a Heating, Ventilation, and Air Conditioning (HVAC) system operating in a library building was conducted. The operating HVAC system was studied in terms of the provided indoor air conditions and energy consumption level. The fieldwork measurements showed that the HVAC system is not capable of providing the desired indoor air conditions based on...
متن کاملFully Fresh Air Air-conditioning System Equipped with Double Heat Pipe Based Heat Recovery Technology
The using of double heat pipe based heat exchanger (HPHX) in a conventional fully fresh air air-conditioning (AC) system was examined in the present study. The fabricated HPHXs were tested under the actual conditions and the measured data were used to study the performance of the existing AC system (System A) and AC system equipped with the double HPHX (System B) for a yearly operation through ...
متن کاملEvaluation of Peak Shifting and Energy Saving Potential of Ice Storage Based Air Conditioning Systems in Iran
Thermal energy storage (TES) system has been introduced as a practical facility for shifting load from peak hours to off-peak hours. Because of different energy consumption during day and night, peak and off peak period is created on load curve. Ice storage technology which is a kind of TES system, is implemented in different points of the world with the purpose of solving load shifting problem...
متن کامل