Assessing the ABL 500 blood gas analyser

نویسندگان

  • B. Gouget
  • R. Andriamahatratra
  • Y. Gourmelin
  • A. Truchaud
چکیده

The ABL 500 blood gas analyser from Radiometer has cordless electrodes and does not use a humidifier for calibrating gases. During the evaluation of the analytical performance of this instrument, the problem of p0(2) accuracy was approached by comparing the values obtained with two kinds of tonometry (film and bubble). An acceptable level of imprecision was demonstrated for all measured parameters. For within-run precision, with tonometry, coefficients of variation (CV) were similar, not equals0.37% for pO(2) and similar, not equals0.52% for pCO(2). A CV of 1.76% was found for day-to-day precision for both p0(2) and pCO(2). In the linearity study, with both tonometry methods, and in the inter-instrument comparisons (the ABL was compared with the Ciba Corning 178), pO(2) values obtained on the ABL 500 exhibited a slight overestimation above 150 mmHg (2.2-3.4% at 600 mmHg). This minor discrepancy is discussed with reference to the new design of the pO(2) electrode, the algorithm for pO(2) correction and the tonometry procedure. The results reported in this paper stress the importance of pO(2) accuracy assessment for the evaluation of blood gas analysers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implementation of the ABL-90 blood gas analyzer in a ground-based mobile emergency care unit

Point-of Care analysis is increasingly being applied in the prehospital scene. Arterial blood gas analysis is one of many new initiatives adding to the diagnostic tools of the prehospital physician. In this paper we present a study on the feasibility of the Radiometer ABL-90 in a ground-based Mobile Emergency Care Unit and report on some clinical situations in which the apparatus has proven ben...

متن کامل

Comparison of blood gas and electrolyte test results from the Gem-Premier and the ABL-70 versus a conventional laboratory analyzer.

Blood gas analyzers serve a critical role in providing information that reflects patient homeostasis. This study was undertaken to evaluate the accuracy, reliability, consistency, and bias of the Radiometer ABL-70 point of care blood gas analyzer. Thirty samples were gathered for analysis of pH, pCO2, pO2, sodium, potassium, sodium bicarbonate, and base excess. Twenty-nine samples were gathered...

متن کامل

Point - f - c re glucose mo it ring on the eonatal unitjpc

Aim: This study aims to compare the accuracy and precision of the Nova StatStrip glucometer against the Radiometer ABL gas analyser. Based on the results, to establish if the Nova StatStrip glucometer could be adopted as a reliable alternative for near-patient glucose monitoring on the neonatal unit. Methods: Seven hundred twenty-eight paired samples were collected prospectively from babies on ...

متن کامل

Clinical evaluation of the accuracy and precision of the CDI 500 in-line blood gas monitor with and without gas calibration.

During cardiopulmonary bypass blood gases can be analyzed with laboratory equipment or with an in-line monitor giving instant results. The manufacturer of the CDI 500 in-line blood gas monitor recommends gas calibration before use. In acute cases there may not be time to perform a gas calibration. We hypothesized that after calibration against laboratory results, the CDI values of pH, pO2, and ...

متن کامل

Detection of SARS coronavirus RNA in the cerebrospinal fluid of a patient with severe acute respiratory syndrome.

and the constant bias of 0.2 mmol/L ( 0.53 to 0.05) is acceptable. As also shown in Fig. 1, the difference between the two methods is independent of leukocyte concentration up to at least 450 10 cells/L. White cells, which interfere during spectrophotometric measurement of Hb on automated hematology analyzers, are ultrasonically lysed in the cooximeter of the blood gas analyzer. This together w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of Automatic Chemistry

دوره 13  شماره 

صفحات  -

تاریخ انتشار 1991