Tibial plateau fracture repairs augmented with calcium phosphate cement have higher in situ fatigue strength than those with autograft.
نویسندگان
چکیده
OBJECTIVES This study compared the biomechanical fatigue strength of calcium phosphate augmented repairs versus autogenous bone graft (ABG) repairs in lateral tibia plateau fractures. METHODS Eight matched pairs of tibias (six male, two female; age, 75 ± 14 years) were harvested from fresh-frozen cadavers. Reproducible split-depression fractures were simulated and repaired by an orthopaedic traumatologist using a lateral tibial plateau plate. One tibia from each donor was randomly assigned to either calcium phosphate (Callos; Acumed, Hillsboro, OR) or ABG as augmentation. The femoral component of a hemitotal knee arthroplasty was attached to the actuator of a servohydraulic press and centered above the repair site. Cyclic, physiological compression loads were applied at 4Hz starting with a maximum load of 15% body weight and increasing by 15% body weight every 70,000 cycles. Loading conditions were determined from calculations of weight distribution, joint contact area, and gait characterization from existing literature. Repair site depression and stiffness were measured at regular intervals. Specimens were then loaded to failure at 1 mm/min. RESULTS Calcium phosphate augmented repairs subsided less and were more stiff during the fatigue loading than were ABG repairs at the 70,000, 140,000, and 210,000 cycle intervals (P < 0.03) All repairs survived to 210,000 cycles. The average ultimate load of the calcium phosphate repairs was 2241 ± 455 N (N = 6) and 1717 ± 508 N (N = 8) for ABG repairs (P = 0.02). CONCLUSION Calcium phosphate repairs have significantly higher fatigue strength and ultimate load than ABG repairs and may increase the immediate weightbearing capabilities of the repaired knee.
منابع مشابه
Minimal internal fixation and calcium-phosphate cement in the treatment of fractures of the tibial plateau. A pilot study.
We used calcium-phosphate cement combined with minimal internal fixation to treat 49 fractures of the lateral tibial plateau. There were 25 split depression fractures, 22 pure depression fractures and two bicondylar fractures. Anatomical reduction was obtained in 38 fractures, satisfactory reduction in nine and imperfect reduction in two. Of 44 patients reviewed at one year, 33 were rated as ha...
متن کاملOsseous vitality in single photon emission computed tomography/computed tomography (SPECT/CT) after balloon tibioplasty of the tibial plateau: a case series
BACKGROUND The minimally invasive, balloon-assisted reduction and cement-augmented internal fixation of the tibial plateau is an innovative surgical procedure for tibial plateau fractures. The close proximity of balloons and cement to the knee joint poses a potential risk for osteonecrosis; especially in the case of thin bone lamellae. However, there are no studies about the vitality of the cem...
متن کاملFatigue performance of a high-strength, degradable calcium phosphate bone cement.
Calcium phosphate cements (CPCs) are clinically used as injectable materials to fill bone voids and to improve hardware fixation in fracture surgery. In vivo they are dynamically loaded; nonetheless little is known about their fatigue properties. The aim of this study was to, for the first time, investigate the fatigue performance of a high-strength, degradable (brushitic) CPC, and also evaluat...
متن کاملHigh early strength calcium phosphate bone cement: effects of dicalcium phosphate dihydrate and absorbable fibers.
Calcium phosphate cement (CPC) sets in situ to form resorbable hydroxyapatite with chemical and crystallographic similarity to the apatite in human bones, hence it is highly promising for clinical applications. The objective of the present study was to develop a CPC that is fast setting and has high strength in the early stages of implantation. Two approaches were combined to impart high early ...
متن کاملInjectable calcium phosphate cement for augmentation around cancellous bone screws. In vivo biomechanical studies.
In lower cancellous apparent bone density, it can be difficult to achieve adequate screw fixation and hence stable fracture fixation. Different strategies have been proposed, one of them is through augmentation using calcium phosphate cement in the region at or close to the screw thread itself. To support the hypothesis of an improved screw fixation technique by augmentation of the bone surroun...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of orthopaedic trauma
دوره 25 2 شماره
صفحات -
تاریخ انتشار 2011