Evaluation of the BMC glucose oxidase/peroxidase-4-aminophenazone-phenol procedure for glucose as adapted to the Technicon SMAC.

نویسندگان

  • G V Purcell
  • D B Behenna
  • P R Walsh
چکیده

We evaluated the analytical performance of Trinder's glucose oxidase (EC 1.1.3.4)/peroxidase (EC 1.11.1.7) 4-aminophenazone-phenol method for the quantification of serum glucose as adapted to the Technicon SMAC. Our results correlated well with those by the routine SMAC glucose oxidase/peroxidase 3-methyl-2-benzothiazolinone hydrazone-N,N-dimethylaniline method (y = 1.02x - 49.4; r = 0.99) and the glucose oxidase oxygen-rate method (y = 0.99x + 14; r = 0.99) with the Beckman Glucose Analyzer. Sample-to-sample interaction was less than 1%. Ascorbic acid or uric acid in concentrations as high as 200 mg/L were without demonstrable effect on results for glucose. Intra- and inter-assay precisions (CV) were 1.6 and 2.3%, respectively. The upper limit of linearity was about 5 g/L. Adaptation of the Trinder method for glucose to the SMAC is simple and provides an analytically acceptable and economical alternative to the methods ordinarily used with the SMAC.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the co-immobilized hexokinase/glucose-6-phosphate dehydrogenase method for glucose, as adapted to the Technicon SMAC.

We assessed the analytical performance of the co-immobilized hexokinase (EC 2.7.1.1) and glucose-6-phosphate dehydrogenase (EC 1.1.1.49) method for D-glucose analysis on the Technicon SMAC. The enzyme-containing coils were usable for one month, or 12 000 tests. Bilirubin, hemoglobin, lipemia, creatinine, uric acid, citric acid, and ascorbic acid did not interfere. Results with this method were ...

متن کامل

Some improvements in operation of the Technicon SMAC system.

In December 1977 a Technicon SMAC system for continuous-flow analysis was installed in our laboratory. Most of the initial problems were solved with the aid of Technicon staff, but several faults persisted that we had to overcome ourselves. Having attended a recent SMAC Users Meeting in Edinburgh, we were sufficiently encouraged to offer relevant details in print. Because the SMAC system comput...

متن کامل

Enzymatic determination of glucose in milk samples by sequential injection analysis.

The present work describes a comparative study involving two sequential injection enzymatic procedures for the spectrophotometric determination of glucose in milk samples. The determinations were based on the use of the enzymes, glucose oxidase and peroxidase, in solution or immobilized, and 4-aminophenazone and phenol as chromogenic reagents. In the first procedure, 8.4 IU of glucose oxidase a...

متن کامل

Evaluation of an automated glucose-oxidase procedure.

We evaluated a slight modification of the automated oxidase/peroxidase method for glucose determination in blood with use of 4-aminophenazone [J. Clin. Pathol. 22, 246 (1969)]. Nonsugar reducing substances did not interfere, except for ascorbic acid in very high concentrations. Lipemic sera gave slightly lower values. Values for reproducibility, specificity, and sensitivity were closer to such ...

متن کامل

Kinetic enzymatic method for automated determination of glucose in blood and serum.

Studies are reported on the reaction kinetics of the glucose assay according to Trinder which involves the specific oxidation of glucose by glucose oxidase and the determination of the hydrogen peroxide released by means of phenol and 4-aminophenazone in the presence of peroxidase. The results have been used to develop a general kinetic fixed-time method for the analysis of glucose in whole blo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 25 10  شماره 

صفحات  -

تاریخ انتشار 1979