Off-resonance binomial composite pulses in 2D and 3D fat/water imaging at 0.5 T.

نویسندگان

  • X P Zhu
  • C E Hutchinson
  • P B Chilvers
  • G A Morris
  • J M Hawnaur
  • C J Taylor
چکیده

A new method of acquiring two-dimensional (2D) and three-dimensional (3D) fat/water decomposed images on a 0.5 T magnetic resonance (MR) imaging system is described. The method uses a gradient-recalled echo (GRE) sequence incorporating a composite 121 pulse, originally used for magnetization transfer contrast (MTC) experiments, for frequency-selective pre-saturation. By applying the 121 pulse off resonance, a sharp discrimination between the chemically shifted water and fat signals may be obtained using a composite pulse as short as 4 ms. Phantom studies demonstrate that suppression ratios as high as 50:1 are achievable. The new method has been applied to volunteers and patients, and good fat/water images of limb, abdomen, head and neck obtained. The new method can be incorporated into other pulse sequences related to GRE, such as phase contrast (PC) and time-of-flight (TOF), and represents the first practical (i.e. rapid) method for 3D fat/water imaging at an operating field as low as 0.5 T.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid fat suppression in MRI of the breast with short binomial pulses.

PURPOSE To develop a faster method of fat suppression for use in dynamic contrast enhanced MRI of the breast. MATERIALS AND METHODS A method of fast fat suppression is presented using spatially nonselective rapid binomial pulses. In contrast to conventional binomial frequency-selective pulses, these short pulses are applied without interpulse delay, allowing for very rapid spectrally selectiv...

متن کامل

Spectrally selective imaging with wideband balanced steady-state free precession MRI.

PURPOSE Unwanted, bright fat signals in balanced steady-state free precession sequences are commonly suppressed using spectral shaping. Here, a new spectral-shaping method is proposed to significantly improve the uniformity of stopband suppression without compromising the level of passband signals. METHODS The proposed method combines binomial-pattern excitation pulses with a wideband balance...

متن کامل

Designing long-T2 suppression pulses for ultrashort echo time imaging.

Ultrashort echo time (UTE) imaging has shown promise as a technique for imaging tissues with T2 values of a few milliseconds or less. These tissues, such as tendons, menisci, and cortical bone, are normally invisible in conventional magnetic resonance imaging techniques but have signal in UTE imaging. They are difficult to visualize because they are often obscured by tissues with longer T2 valu...

متن کامل

Water Selective Imaging and bSSFP Banding Artifact Correction in Humans and Small Animals at 3T and 7T, Respectively

INTRODUCTION The purpose of this paper is to develop an easy method to generate both fat signal and banding artifact free 3D balanced Steady State Free Precession (bSSFP) images at high magnetic field. METHODS In order to suppress fat signal and bSSFP banding artifacts, two or four images were acquired with the excitation frequency of the water-selective binomial radiofrequency pulse set On R...

متن کامل

Robust large field-of-view water selective imaging at 3T with parallel transmission

Introduction: Spectral fat suppressed or water selective imaging (e.g. using 1331 binomial pulses) for large fields-of-view is difficult to achieve, particularly at higher field because of problems in achieving a high-quality shim of the static B0 field. Off resonance effects cause the water and fat resonances to be position dependent, causing water only selection/fat suppression to fail in som...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of radiology

دوره 68 806  شماره 

صفحات  -

تاریخ انتشار 1995