Comparison of cement pressurisation in flanged and unflanged acetabular cups

نویسندگان

  • Rajarshi Bhattacharya
  • Fahad G Attar
  • Sarah Green
  • Andrew Port
چکیده

BACKGROUND This biomechanical study examined difference in cement pressures generated by flanged and unflanged acetabular cups in hip arthroplasty. METHOD Using a model acetabulum, cement was inserted and pressurised followed by cup insertion and pressurisation. Pressures were recorded using transducers in the acetabulum. We compared Charnley Ogee (flanged), Exeter contemporary (flanged) and Exeter low profile (unflanged) cups using Simplex and CMW1 cements in turn. RESULTS Using Simplex, Charnley Ogee cup generated highest initial peak pressure and overall mean pressure. Exeter unflanged cup generated higher initial and mean pressures compared to Exeter flanged cup. With CMW, there was no significant difference between the pressures generated by the cups. CONCLUSIONS Our experiment suggests that flanged cups do not consistently generate significantly higher cement pressures compared to unflanged cups.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of flanged and unflanged acetabular cup design

BACKGROUND AND PURPOSE Adequate depth of cement penetration and cement mantle thickness is important for the durability of cemented cups. A flanged cup, as opposed to unflanged, has been suggested to give a more uniform cement mantle and superior cement pressurization, thus improving the depth of cement penetration. This hypothesis was tested experimentally. MATERIALS AND METHODS The same cup...

متن کامل

Socket design and cement pressurisation in the Charnley low-friction arthroplasty.

An experimental evaluation was made of the efficacy of an unflanged cup, an ogee-flanged cup and the Exeter pressuriser in the pressurisation of acetabular cement. Only a very modest injection pressure could be generated through an unflanged socket and even this was readily lost as the socket "bottomed out". The ogee-flanged socket gave a consistently high injection pressure which could be main...

متن کامل

Sealing the acetabular notch in cemented total hip arthroplasty. A radiological review of 380 cases.

Recent in vitro work has shown that sealing the acetabular notch with bone graft in bovine acetabulum samples results in improved cement penetration in the acetabular bone during total hip arthroplasty. Successful sealing of the notch may be identified on postoperative films by a lack of cement extrusion. This study aimed to assess the clinical effectiveness of this technique in preventing ceme...

متن کامل

An improved acetabular cementing technique in total hip arthroplasty. Aspiration of the iliac wing.

We have evaluated the effect of vacuum aspiration of the iliac wing on the osseointegration of cement into the acetabulum. We entered a total of 40 patients undergoing primary total hip arthroplasty into two consecutive study groups. Group 1 underwent acetabular cement pressurisation for 60 seconds before insertion of the acetabular component. Group 2 had the same pressurisation with simultaneo...

متن کامل

Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs

Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2012