Doppler cerebrovascular examination: improved results with refinements in technique.
نویسندگان
چکیده
Doppler ultrasonic assessment of extracranial carotid occlusive disease has been modified to decrease the incidence of false positive and negative diagnoses. The technique, which assessed directional flow in the frontal artery and the influence of sequential compression of each temporal, infraorbital, facial and common carotid artery, was performed on 152 vessels visualized by contrast arteriography. Presence or absence of significant (greater than 50%) stenosis or occlusion of the internal carotid artery was identified correctly in 150 vessels (98.7%). Inasmuch as the classic temporal artery compression test only detected 39 of the 61 abnormal Doppler studies (64%), the more complete examination is recommended for screening patients for significant carotid artery obstruction.
منابع مشابه
Clinical implications of the Doppler cerebrovascular examination: a correlation with angiography.
A directional Doppler ultrasound cerebrovascular examination was compared with angiographical findings of 152 internal carotid arteries. The Doppler examination was abnormal in 36 of 38 (95%) arteries with occlusion or stenosis greater than 75%. Of 63 arteries with lesser degrees of stenosis, the Doppler examination identified only four. There were no false-positive Doppler examinations. If the...
متن کاملFrequency of Opium Addiction with Ischemic Stroke Patients and Comparing Their Cerebrovascular Doppler Ultrasound Alternations to Non-Addicts
Background: Ischemic stroke is a major cause of mortality and morbidity worldwide. Various studies on the etiology of this disease are in progress. Some studies have suggested that opium abuse may is associated with increased risk of ischemic stroke. The present study aimed to analyze the frequency of opium addiction and to compare cerebrovascular ultrasound patients’ changes to non-addicts. Me...
متن کاملCarotid Physiology with Ocular Pneumoplethysmography
References 1. Curry GR, White DN: Color coded ultrasonic differential velocity arterial scanner (Echoflow). Ultrasound Med Biol 4: 27-35, 1978 2. Barnes RW, Russell HE, Bone GE, Slaymaker EE: Doppler cere brovascular examination: Improved results with refinements in tech nique. Stroke 8: 468-71, 1977 3. Gee W, Mehigan JT, Wylie EJ: Measurement of collateral cerebral hemispheric blood pressure...
متن کاملCarotid physiology with ocular pneumoplethysmography.
References 1. Curry GR, White DN: Color coded ultrasonic differential velocity arterial scanner (Echoflow). Ultrasound Med Biol 4: 27-35, 1978 2. Barnes RW, Russell HE, Bone GE, Slaymaker EE: Doppler cere brovascular examination: Improved results with refinements in tech nique. Stroke 8: 468-71, 1977 3. Gee W, Mehigan JT, Wylie EJ: Measurement of collateral cerebral hemispheric blood pressure...
متن کاملCarotid Physiology with Ocular Pneumoplethysmography
References 1. Curry GR, White DN: Color coded ultrasonic differential velocity arterial scanner (Echoflow). Ultrasound Med Biol 4: 27-35, 1978 2. Barnes RW, Russell HE, Bone GE, Slaymaker EE: Doppler cere brovascular examination: Improved results with refinements in tech nique. Stroke 8: 468-71, 1977 3. Gee W, Mehigan JT, Wylie EJ: Measurement of collateral cerebral hemispheric blood pressure...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Stroke
دوره 8 4 شماره
صفحات -
تاریخ انتشار 1977