Multichannel thin-film electrode for intramuscular electromyographic recordings.
نویسندگان
چکیده
It is currently not possible to record electromyographic (EMG) signals from many locations concurrently inside the muscle in a single wire electrode system. We developed a thin-film wire electrode system for multichannel intramuscular EMG recordings. The system was fabricated using a micromachining process, with a silicon wafer as production platform for polyimide-based electrodes. In the current prototype, the flexible polymer structure is 220 microm wide, 10 microm thick, and 1.5 cm long, and it has eight circular platinum-platinum chloride recording sites of 40-microm diameter distributed along the front and back surfaces with 1,500-microm intersite spacing. The system prototype was tested in six experiments where the electrode was implanted into the medial head of the gastrocnemius muscle of rabbits, perpendicular to the pennation angle of the muscle fibers. Asynchronous motor unit activity was induced by eliciting the withdrawal reflex or sequential crushes of the sciatic nerve using a pair of forceps. Sixty-seven motor units were identified from these recordings. In the bandwidth 200 Hz to 5 kHz, the peak-to-peak amplitude of the action potentials of the detected motor units was 75 +/- 12 muV and the root mean square of the noise was 1.6 +/- 0.4 muV. The noise level and amplitude of the action potentials were similar for measures separated by up to 40 min. The experimental tests demonstrated that thin film is a promising technology for a new type of flexible-wire intramuscular EMG recording system with multiple detection sites.
منابع مشابه
Innovative Methodology Multichannel thin-film electrode for intramuscular electromyographic recordings
Dario Farina, Ken Yoshida, Thomas Stieglitz, and Klaus Peter Koch Center for Sensory-Motor Interaction (SMI), Department of Health Science and Technology, Aalborg University, Aalborg, Denmark; Biomedical Engineering Department, Indiana University-Purdue University, Indianapolis, Indianapolis, Indiana; Department of Medical Engineering and Neuroprosthetics, Fraunhofer Institute for Biomedical En...
متن کاملA strategy for degradation of 2,5-dichlorophenol using its photoelectrocatalytic oxidation on the TiO2/Ti thin film electrode
In this work, the photoelectrocatalytic (PEC) degradation of 2,5-dichlorophenol can be used for its removal from aqueous solution. To study this activity, a TiO2 thin film modified titanium sheet (TiO2/Ti) was fabricated by anodizing Ti plates using a two electrode system under the constant bias voltage of 20 V for 20 min in a solution of 0.2% (v/v) HF followed by calcinat...
متن کاملChronic multichannel neural recordings from soft regenerative microchannel electrodes during gait
Reliably interfacing a nerve with an electrode array is one of the approaches to restore motor and sensory functions after an injury to the peripheral nerve. Accomplishing this with current technologies is challenging as the electrode-neuron interface often degrades over time, and surrounding myoelectric signals contaminate the neuro-signals in awake, moving animals. The purpose of this study w...
متن کاملElectromyographic measures of muscle activation and changes in muscle architecture of human elbow flexors during fatiguing contractions.
The study compared changes in intramuscular and surface recordings of EMG amplitude with ultrasound measures of muscle architecture of the elbow flexors during a submaximal isometric contraction. Ten subjects performed a fatiguing contraction to task failure at 20% of maximal voluntary contraction force. EMG activity was recorded in biceps brachii, brachialis, and brachioradialis muscles using ...
متن کاملUltrasound-guided insertion of intramuscular electrodes into suboccipital muscles in the non-human primate.
The head-neck system is highly complex from a biomechanical and musculoskeletal perspective. Currently, the options for recording the recruitment of deep neck muscles in experimental animals are limited to chronic approaches requiring permanent implantation of electromyographic electrodes. Here, we describe a method for targeting deep muscles of the dorsal neck in non-human primates with intram...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied physiology
دوره 104 3 شماره
صفحات -
تاریخ انتشار 2008