Long-distance transfer and routing of static magnetic fields.

نویسندگان

  • C Navau
  • J Prat-Camps
  • O Romero-Isart
  • J I Cirac
  • A Sanchez
چکیده

We show how the static magnetic field of a finite source can be transferred and routed to arbitrary long distances. This is achieved by using transformation optics, which results in a device made of a material with a highly anisotropic magnetic permeability. We show that a simplified version of the device, made by a superconducting-ferromagnet hybrid, also leads to an excellent transfer of the magnetic field. The latter is demonstrated with a proof-of-principle experiment where a ferromagnet tube coated with a superconductor improves the transfer of static magnetic fields with respect to conventional methods by a 400% factor over distances of 14 cm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی میزان مواجهه شغلی با میدان های مغناطیسی پایا واثرات بهداشتی آن در مراکز تصویر برداری تشدید مغناطیسی

 Background and aim:  Magnetic resonance imaging as one of the best medical scanning technique is considered to be the most important sources of static magnetic fields. The staffs of MRI ´s units frequently exposed to these static magnetic fields. This study aims to determine the occupational exposure level to mentioned field and its related health effects in MRI´s units.    Methods:  The occup...

متن کامل

Quasi-Static Theory for Uniaxial Chiral Omega Media

The problem of unbounded uniaxial chiral omega media in the presence of both static electric and magnetic point charges is investigated. For this purpose scalar electric and magnetic potentials in these media are introduced. Using these potentials, the corresponding electric and magnetic fields are determined. The similar problem of static electric and magnetic current sources with the goal of ...

متن کامل

Does Exposure to Static Magnetic Fields Generated by Magnetic Resonance Imaging Scanners Raise Safety Problems for Personnel?

MRI workers are occupationally exposed to static and time-varying gradient magnetic fields.  While the 24-hour time-averaged exposure to static magnetic fields is about a few mT, the maximum static field strength can be as high as 500 mT during patient setup. Over the past several years, our laboratory has performed extensive experiments on the health effects of exposure of animal models and h...

متن کامل

The effect of 17 days exposure to static magnetic fields on the hypothalamic-pituitary-gonadal axis in the male rat

Power stations produce a range of magnetic fields more than 20 mT which are harmful to those working or living around them. Several investigators have reported an increased health risk due to exposure to electric and magnetic fields (EMF) at 50 and 60 Hz. Several studies have been reported especially with increased tumor incidence, effects on reproduction and development, and neural and behavio...

متن کامل

The effect of 17 days exposure to static magnetic fields on the hypothalamic-pituitary-gonadal axis in the male rat

Power stations produce a range of magnetic fields more than 20 mT which are harmful to those working or living around them. Several investigators have reported an increased health risk due to exposure to electric and magnetic fields (EMF) at 50 and 60 Hz. Several studies have been reported especially with increased tumor incidence, effects on reproduction and development, and neural and behavio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physical review letters

دوره 112 25  شماره 

صفحات  -

تاریخ انتشار 2014